Measuring forces and frequency during active compression decompression cardiopulmonary resuscitation: a device for training, research and real CPR

被引:12
作者
Baubin, M [1 ]
Haid, C [1 ]
Hamm, P [1 ]
Gilly, H [1 ]
机构
[1] Univ Innsbruck, Dept Anaesthesia, A-6020 Innsbruck, Austria
关键词
cardiopulmonary resuscitation; CPR monitoring; active compression-decompression; CPR training; CPR quality assessment;
D O I
10.1016/S0300-9572(99)00107-0
中图分类号
R4 [临床医学];
学科分类号
1002 [临床医学]; 100602 [中西医结合临床];
摘要
Active compression decompression (ACD) cardiopulmonary resuscitation (CPR) is possibly a superior alternative to standard (STD) CPR, but an optimal compression and decompression pattern has to be ensured. ACD-CPR can be evaluated during CPR training sessions using commercially available manikins; however devices for recording compression and decompression forces or frequency during real CPR are lacking, Using the Ambu CardioPump(R) without changing its mechanical characteristics, two force transducers were integrated into the ACD device. Using specially designed electronics and a portable computer, compression and decompression forces were measured and displayed continuously and compression frequency and the compression decompression phase are calculated on-line during real CPR action. All measured parameters were stored on a hard disk for later retrieval and analysis. Linearity of force measurement was better than 6% within a -250- + 500 N range. The error in repeatability was below 5% thus outperforming the original mechanical force measurement system of the Ambu CardioPump(R). Compression frequency was calculated very accurately (error < 1%). The system has been successfully used during CPR training, during ACD-CPR in 37 corpses under research conditions and in five out-of-hospital CPR casualties. Simple and safe in use, our modified CardioPump(R) with integrated electronics provides an important, technically advanced solution for monitoring ACD-CPR on-line. It warrants quality assurance during ACD-CPR training and in real CPR scenarios and guarantees accurate recording of compression and decompression forces and compression frequency. (C) 1999 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:17 / 24
页数:8
相关论文
共 13 条
[1]
*AM HEART ASS, 1992, JAMA-J AM MED ASSOC, V268, P2189
[2]
Rescuer's work capacity and duration of cardiopulmonary resuscitation [J].
Baubin, M ;
Schirmer, M ;
Nogler, M ;
Semenitz, B ;
Falk, M ;
Kroesen, G ;
Hortnagl, H ;
Gilly, H .
RESUSCITATION, 1996, 33 (02) :135-139
[3]
Chest injuries after active compression-decompression cardiopulmonary resuscitation (ACD-CPR) in cadavers [J].
Baubin, M ;
Rabl, W ;
Pfeiffer, KP ;
Benzer, A ;
Gilly, H .
RESUSCITATION, 1999, 43 (01) :9-15
[4]
COMPRESSION CHARACTERISTICS OF CPR MANNEQUINS [J].
BAUBIN, MA ;
GILLY, H ;
POSCH, A ;
SCHINNERL, A ;
KROESEN, GA .
RESUSCITATION, 1995, 30 (02) :117-126
[5]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]
ACTIVE COMPRESSION-DECOMPRESSION - A NEW METHOD OF CARDIOPULMONARY-RESUSCITATION [J].
COHEN, TJ ;
TUCKER, KJ ;
LURIE, KG ;
REDBERG, RF ;
DUTTON, JP ;
DWYER, KA ;
SCHWAB, TM ;
CHIN, MC ;
GELB, AM ;
SCHEINMAN, MM ;
SCHILLER, NB ;
CALLAHAM, ML .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1992, 267 (21) :2916-2923
[7]
The study of the effectiveness of chest compressions using the CPR-plus [J].
Elding, C ;
Baskett, P ;
Hughes, A .
RESUSCITATION, 1998, 36 (03) :169-173
[8]
Single rescuer adult basic life support - An advisory statement from the Basic Life Support Working Group of the International Liaison Committee on Resuscitation (ILCOR) [J].
Handley, AJ ;
Becker, LB ;
Allen, M ;
vanDrenth, A ;
Kramer, EB ;
Montgomery, WH .
RESUSCITATION, 1997, 34 (02) :101-108
[9]
The 1998 European Resuscitation Council guidelines for adult single rescuer basic life support - A statement from the Working Group on Basic Life Support, and approved by the executive committee of the European Resuscitation Council [J].
Handley, AJ ;
Bahr, J ;
Baskett, P ;
Bossaert, L ;
Chamberlain, D ;
Dick, W ;
Ekstrom, L ;
Juchems, R ;
Kettler, D ;
Marsden, A ;
Moeschler, O ;
Monsierurs, K ;
Parr, M ;
Petit, P ;
Van Drenth, A .
RESUSCITATION, 1998, 37 (02) :67-80
[10]
*KELL MED PROD, 1994, CPRPLUS CARD COMPR M