Desorption sonic spray ionization for (high) voltage-free ambient mass spectrometry

被引:261
作者
Haddad, Renato [1 ]
Sparrapan, Regina [1 ]
Eberlin, Marcos N. [1 ]
机构
[1] Univ Estadual Campinas, Inst Chem, ThoMSon Mass Spect Lab, BR-13084971 Campinas, SP, Brazil
关键词
D O I
10.1002/rcm.2680
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Sonic spray ionization is shown to create a supersonic cloud of charged droplets able to promote efficient desorption and ionization of drugs directly from the surfaces of commercial drug tablets at ambient conditions. Compared with desorption electrospray ionization (DESI), desorption sonic spray ionization (DeSSI) is advantageous since it uses neither heating nor high voltages at the spray capillary. DeSSI therefore provides a more friendly environment in which to perform ambient mass spectrometry (MS). DeSSI-MS is herein evaluated for the analysis of drug tablets, and found to be, in general, as sensitive as DESI-MS. The (high) voltage-free DeSSI method provides, however, cleaner mass spectra with less abundant solvent cluster ions and with enough abundant analyte signal for tandem mass spectrometry (MS/MS). These features may therefore facilitate the DeSSI-MS detection of low molar mass components or impurities, or both. The higher-velocity supersonic DeSSI spray also facilitates matrix penetration thus providing more homogenous sampling and longer lasting ion signals. Copyright (c) 2006 John Wiley & Sons, Ltd.
引用
收藏
页码:2901 / 2905
页数:5
相关论文
共 15 条
[1]   Versatile new ion source for the analysis of materials in open air under ambient conditions [J].
Cody, RB ;
Laramée, JA ;
Durst, HD .
ANALYTICAL CHEMISTRY, 2005, 77 (08) :2297-2302
[2]   Desorption electrospray ionization of explosives on surfaces:: Sensitivity and selectivity enhancement by reactive desorption electrospray ionization [J].
Cotte-Rodríguez, I ;
Takáts, Z ;
Talaty, N ;
Chen, HW ;
Cooks, RG .
ANALYTICAL CHEMISTRY, 2005, 77 (21) :6755-6764
[3]   ELECTROSPRAY IONIZATION FOR MASS-SPECTROMETRY OF LARGE BIOMOLECULES [J].
FENN, JB ;
MANN, M ;
MENG, CK ;
WONG, SF ;
WHITEHOUSE, CM .
SCIENCE, 1989, 246 (4926) :64-71
[4]  
Hirabayashi A, 1996, RAPID COMMUN MASS SP, V10, P1703, DOI 10.1002/(SICI)1097-0231(199610)10:13<1703::AID-RCM687>3.0.CO
[5]  
2-J
[6]   Desorption electrospray ionization mass spectrometry for the analysis of pharmaceuticals and metabolites [J].
Kauppila, TJ ;
Wiseman, JM ;
Ketola, RA ;
Kotiaho, T ;
Cooks, RG ;
Kostiainen, R .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (03) :387-392
[7]   Desorption electrospray ionization mass spectrometry: direct toxicological screening and analysis of illicit Ecstasy tablets [J].
Leuthold, LA ;
Mandscheff, JF ;
Fathi, M ;
Giroud, C ;
Augsburger, M ;
Varesio, E ;
Hopfgartner, G .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (02) :103-110
[8]  
MARQUES LA, 2006, UNPUB RAPID COMMUN M, V20
[9]   Analysis of solids, liquids, and biological tissues using solids probe introduction at atmospheric pressure on commercial LC/MS instruments [J].
McEwen, CN ;
McKay, RG ;
Larsen, BS .
ANALYTICAL CHEMISTRY, 2005, 77 (23) :7826-7831
[10]   Amino acid clusters formed by sonic spray ionization [J].
Takats, Z ;
Nanita, SC ;
Cooks, RG ;
Schlosser, G ;
Vekey, K .
ANALYTICAL CHEMISTRY, 2003, 75 (06) :1514-1523