The theoretical aspects of the instrumentation of a weak inertia parietal thermal sensor.

被引:33
作者
Bourouga, B [1 ]
Goizet, V [1 ]
Bardon, JP [1 ]
机构
[1] ISITEM, Lab Thermocinet, UMR CNRS 6607, F-44306 Nantes 3, France
关键词
measurement; temperature; heat flux; sensor; instrumentation; response time; sensitivity; accuracy;
D O I
10.1016/S1290-0729(00)00192-6
中图分类号
O414.1 [热力学];
学科分类号
摘要
From a simple semi-infinite model, we present theoretical developments allowing the optimisation of the instrumentation of parietal thermal sensors. Generally equipped with two thin thermocouples, these sensors must present a weak thermal inertia in order to characterise thermal boundary conditions in fast unsteady regime. Performances of such sensors are described by three characteristics: response time, measurement sensitivity and accuracy. For a given material, the constraint on the response time determines diameter and position of the second thermocouple. In a second time, the position of the first thermocouple results from a good compromise between measurement sensitivity and accuracy. This compromise depends itself on the sensor response time, particularly at the beginning of the studied thermal phenomena. (C) 2000 Editions scientifiques et medicates Elsevier SAS.
引用
收藏
页码:96 / 109
页数:14
相关论文
共 23 条
[1]  
ASSANIS DN, 1991, 900691 SAE
[2]  
BARDON JP, 1991, SEM EUR SPRINT ECH C
[3]  
BARDON JP, 1995, REV GEN THERM, V34, P15
[4]  
BOUROUGA B, 1998, ACT C SFT MARS, P307
[5]  
CASSAGNE B, 1986, HEAT TRANSFER, V2, P483
[6]  
ENOMOTO Y, 1995, C49601195 SAE
[7]   INFLUENCE OF THE LUBRICANT ON TEMPERATURE DISTRIBUTION IN THE FORGING DIES [J].
GIERZYNSKADOLNA, M ;
PIETRZYK, M ;
KUCHARCZYK, Z ;
LACKI, P .
STEEL RESEARCH, 1995, 66 (10) :424-429
[8]  
Goizet V, 1998, HEAT TRANSFER 1998, VOL 5, P15
[9]  
JACKSON NS, 1990, 900692 SAE
[10]  
Jain V., 1990, J MAT SHAPING TECHNO, V8, P193