Improvement of internal jugular vein cannulation using an ultrasound-guided technique

被引:126
作者
Slama, M [1 ]
Novara, A [1 ]
Safavian, A [1 ]
Ossart, M [1 ]
Safar, M [1 ]
Fagon, JY [1 ]
机构
[1] HOP BROUSSAIS,SERV REANIMAT MED,F-75674 PARIS 14,FRANCE
关键词
ultrasound; venous access; catheterization; critical illness; internal jugular vein;
D O I
10.1007/s001340050432
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective:To determine whether ultrasound guidance can help operators to improve the results of jugular vein access in the ICU, Design: Prospective, randomized study. Setting: General Intensive Care Unit of a University Hospital. Patients: Seven-nine patients were assigned to internal jugular vein cannulation using anatomical landmarks alone (control group, n = 42) or with ultrasound guidance (ultrasound group, n = 37), Intervention: All cannulations were performed by junior house staff under the direct supervision of a senior physician. In the ultrasound group, an ultrasonography (7.5 MHz) was used and the transducer was covered by a sterile sheath, The placement and direction of the cannulating needle were determined on the ultrasound image, Measurements and results: Internal jugular vein cannulation was successful in 37/37 (100 %) patients in the ultrasound group and in 32/32 patients (76 %) in the control group (p < 0.01), Average access time was longer in the control group (235 +/- 408 s vs 95 +/- 174 s, p = 0.06) and carotid artery puncture occurred in five patients in each group (p = 0.83). Jugular cannulation was successful at the first attempt in 26 % in the control group and 43 % in the ultrasound group (p = 0.11). Thirty-two patients (86 %) in the ultrasound group and 23 patients (55 %) in the control group (p < 0.05) were cannulated within 3 min. The cannula could therefore not be inserted within 3 min in 19 patients (45 %) in the control group, Failure was explained by thrombosis (n = 1), small caliber of the internal jugular vein (< 5 mm, n = 3), abnormal vascular relations (n = 3), Among the ten primary failures of cannulation, an internal jugular vein catheter was able to be inserted in four cases by an experienced physician on the side initially selected and with ultrasound guidance in two cases. The catheter was inserted into the contralateral internal jugular vein under ultrasound guidance in the remaining four cases. Conclusion: Ultrasound guidance improved the success rate of jugular vein cannulation in ICU patients. Our results suggest that ultrasound guidance should be used when the internal jugular vein has not been successfully cannulated within 3 min by the external landmark-guided technique.
引用
收藏
页码:916 / 919
页数:4
相关论文
共 17 条
[1]  
BOND DM, 1989, ANESTH ANALG, V68, P699
[2]  
DAILY PO, 1970, ARCH SURG-CHICAGO, V101, P534
[3]  
DEFALQUE RJ, 1974, ANESTH ANALG, V53, P116
[4]   ULTRASOUND-ASSISTED CANNULATION OF THE INTERNAL JUGULAR-VEIN - A PROSPECTIVE COMPARISON TO THE EXTERNAL LANDMARK-GUIDED TECHNIQUE [J].
DENYS, BG ;
URETSKY, BF ;
REDDY, PS .
CIRCULATION, 1993, 87 (05) :1557-1562
[5]   ANATOMICAL VARIATIONS OF INTERNAL JUGULAR-VEIN LOCATION - IMPACT ON CENTRAL VENOUS ACCESS [J].
DENYS, BG .
CRITICAL CARE MEDICINE, 1991, 19 (12) :1516-1519
[6]   PERCUTANEOUS CANNULATION OF INTERNAL JUGULAR VEIN [J].
ENGLISH, ICW ;
FREW, RM ;
PIGOTT, JFG ;
ZAKI, M .
THORAX, 1969, 24 (04) :496-&
[7]   PERCUTANEOUS CANNULATION OF THE INTERNAL JUGULAR VEIN IN PATIENTS WITH COAGULOPATHIES - AN EXPERIENCE BASED ON 1,000 ATTEMPTS [J].
GOLDFARB, G ;
LEBREC, D .
ANESTHESIOLOGY, 1982, 56 (04) :321-323
[8]   SAFER JUGULAR VEIN CANNULATION - RECOGNITION OF ARTERIAL PUNCTURE AND PREFERENTIAL USE OF THE EXTERNAL JUGULAR ROUTE [J].
JOBES, DR ;
SCHWARTZ, AJ ;
GREENHOW, DE ;
STEPHENSON, LW ;
ELLISON, N .
ANESTHESIOLOGY, 1983, 59 (04) :353-355
[9]  
KOSKI EMJ, 1992, CRIT CARE MED, V3, P424
[10]   DOPPLER LOCALIZATION OF THE INTERNAL JUGULAR VEIN FACILITATES CENTRAL VENOUS CANNULATION [J].
LEGLER, D ;
NUGENT, M .
ANESTHESIOLOGY, 1984, 60 (05) :481-482