Liver Fibrosis in Viral Hepatitis: Noninvasive Assessment with Acoustic Radiation Force Impulse Imaging versus Transient Elastography

被引:538
作者
Friedrich-Rust, Mireen [1 ]
Wunder, Katrin [1 ]
Kriener, Susanne [2 ]
Sotoudeh, Fariba [1 ]
Richter, Swantje [1 ]
Bojunga, Joerg [1 ]
Herrmann, Eva [3 ]
Poynard, Thierry [4 ]
Dietrich, Christoph F. [5 ]
Vermehren, Johannes [1 ]
Zeuzem, Stefan [1 ]
Sarrazin, Christoph [1 ]
机构
[1] JW Goethe Univ Hosp, Dept Internal Med, D-60590 Frankfurt, Germany
[2] JW Goethe Univ Hosp, Inst Pathol, D-60590 Frankfurt, Germany
[3] Goethe Univ Frankfurt, Fac Med, Inst Biostat & Math Modeling, Frankfurt, Germany
[4] Hosp Pitie Salpetriere, Paris, France
[5] Caritas Hosp, Dept Internal Med 2, Bad Mergentheim, Germany
关键词
STIFFNESS MEASUREMENT; SAMPLING VARIABILITY; BIOCHEMICAL MARKERS; MR ELASTOGRAPHY; IN-VIVO; FIBROTEST; BIOPSY; INDEX;
D O I
10.1148/radiol.2523081928
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare, in a pilot study, acoustic radiation force impulse (ARFI) imaging technology integrated into a conventional ultrasonography (US) system with both transient elastography (TE) and serologic fibrosis marker testing for the noninvasive assessment of liver fibrosis. Materials and Methods: Informed consent was obtained from all subjects, and the local ethics committee approved the study. ARFI imaging involved the mechanical excitation of tissue with use of short-duration acoustic pulses to generate localized displacements in tissue. The displacements resulted in shearwave propagation, which was tracked by using US correlation-based methods and recorded in meters per second. Eighty-six patients with chronic viral hepatitis underwent TE, ARFI imaging, and serum fibrosis marker testing. Results were compared with liver biopsy findings, which served as the reference standard. Results: ARFI imaging (rho = 0.71), TE (rho = 0.73), and serum fibrosis marker test (rho = 0.66) results correlated significantly with histologic fibrosis stage (P < .001). Median ARFI velocities ranged from 0.84 to 3.83 m/sec. Areas under the receiver operating characteristic curve for the accuracy of ARFI imaging, TE, and serum fibrosis marker testing were 0.82, 0.84, and 0.82, respectively, for the diagnosis of moderate fibrosis (histologic fibrosis stage, >= 2) and 0.91, 0.91, and 0.82, respectively, for the diagnosis of cirrhosis. Conclusion: ARFI imaging is a promising US-based method for assessing liver fibrosis in chronic viral hepatitis, with diagnostic accuracy comparable to that of TE in this preliminary study. (c) RSNA, 2009
引用
收藏
页码:595 / 604
页数:10
相关论文
共 33 条
  • [2] An algorithm for the grading of activity in chronic hepatitis C
    Bedossa, P
    Poynard, T
    [J]. HEPATOLOGY, 1996, 24 (02) : 289 - 293
  • [3] Sampling variability of liver fibrosis in chronic hepatitis C
    Bedossa, P
    Dargère, D
    Paradis, V
    [J]. HEPATOLOGY, 2003, 38 (06) : 1449 - 1457
  • [4] Pain experienced during percutaneous liver biopsy
    Castéra, L
    Nègre, I
    Samii, K
    Buffet, C
    [J]. HEPATOLOGY, 1999, 30 (06) : 1529 - 1530
  • [5] Hepatocellular carcinoma and hepatitis C in the United States
    El-Serag, HB
    [J]. HEPATOLOGY, 2002, 36 (05) : S74 - S83
  • [6] Prevalence and factors associated with failure of liver stiffness measurement using FibroScan in a prospective study of 2114 examinations
    Foucher, Juliette
    Castera, Laurent
    Bernard, Pierre-Henri
    Adhoute, Xavier
    Laharie, David
    Bertet, Julien
    Couzigou, Patrice
    de Ledinghen, Victor
    [J]. EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2006, 18 (04) : 411 - 412
  • [7] Reproducibility of transient elastography in the evaluation of liver fibrosis in patients with chronic liver disease
    Fraquelli, Mirella
    Rigamonti, Cristina
    Casazza, Giovanni
    Conte, Dario
    Donato, Maria Francesca
    Ronchi, Guido
    Colombo, Massimo
    [J]. GUT, 2007, 56 (07) : 968 - 973
  • [8] Performance of transient elastography for the staging of liver fibrosis: A meta-analysis
    Friedrich-Rust, Mireen
    Ong, Mei-Fang
    Martens, Swantje
    Sarrazin, Christoph
    Bojunga, Joerg
    Zeuzem, Stefan
    Herrmann, Eva
    [J]. GASTROENTEROLOGY, 2008, 134 (04) : 960 - 974
  • [9] Magnetic resonance elastography for the noninvasive staging of liver fibrosis
    Huwart, Laurent
    Sempoux, Christine
    Vicaut, Eric
    Salameh, Najat
    Annet, Laurence
    Danse, Etienne
    Peeters, Frank
    ter Beek, Leon C.
    Rahier, Jacques
    Sinkus, Ralph
    Horsmans, Yves
    Van Beers, Bernard E.
    [J]. GASTROENTEROLOGY, 2008, 135 (01) : 32 - 40
  • [10] Liver fibrosis: Noninvasive assessment with MR elastography versus aspartate aminotransferase-to-platelet ratio index
    Huwart, Laurent
    Sempoux, Christine
    Salameh, Najat
    Jamart, Jacques
    Annet, Laurence
    Sinkus, Ralph
    Peeters, Frank
    ter Beek, Leon C.
    Horsmans, Yves
    Van Beers, Bernard E.
    [J]. RADIOLOGY, 2007, 245 (02) : 458 - 466