Measurement of MRI scanner performance with the ADNI phantom

被引:130
作者
Gunter, Jeffrey L. [1 ]
Bernstein, Matt A. [1 ]
Borowski, Brett J. [1 ]
Ward, Chadwick P. [1 ]
Britson, Paula J. [1 ]
Felmlee, Joel P. [1 ]
Schuff, Norbert [2 ,3 ]
Weiner, Michael [2 ,3 ]
Jack, Clifford R. [1 ]
机构
[1] Mayo Clin & Mayo Fdn, Rochester, MN 55902 USA
[2] Univ Calif San Francisco, Dept Vet Affairs Med Ctr, San Francisco, CA 94143 USA
[3] Univ Calif San Francisco, Magnet Resonance Unit 114M, San Francisco, CA 94143 USA
基金
美国国家卫生研究院;
关键词
biomedical MRI; diseases; neurophysiology; phantoms; MAGNETIC-RESONANCE IMAGES; GEOMETRIC DISTORTION; QUALITY-ASSURANCE; TEST OBJECTS; 3D PHANTOM; MULTICENTER; REGISTRATION; SPECTROSCOPY; PROTOCOLS; SYSTEMS;
D O I
10.1118/1.3116776
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The objectives of this study are as follows: to describe practical implementation challenges of multisite, multivendor quantitative studies; to describe the MRI phantom and analysis software used in the Alzheimer's Disease Neuroimaging Initiative (ADNI) study, illustrate the utility of the system for measuring scanner performance, the ability to assess gradient field nonlinearity corrections: and to recover human brain images without geometric scaling errors in multisite studies. ADNI is a large multicenter study with each center having its own copy of the phantom. The design of the phantom and analysis software are presented as results from predistribution systematics studies and results from field experience with the phantom at 58 enrolling ADNI sites over a 3 year period. The estimated coefficients of variation intrinsic to measurements of geometry in a single phantom are in the range of 3-5 parts in 10(4). Phantom measurements accurately detect linear and nonlinear scaling in images. Gradient unwarping methods are readily assessed by phantom nonlinearity measurements. Phantom-based scaling correction reduces observed geometric drift in human images by one-third or more. Repair or replacement of phantoms between scans, however, is a confounding factor. The ADNI phantom can be used to assess both scanner performance and the validity of postprocessing image corrections in order to reduce systematic errors in human images. Reduced measurement errors should decrease measurement bias and increase statistical power for measurements of rates of change in the brain structure in AD treatment trials. Perhaps the greatest practical value of incorporating ADNI phantom measurements in a multisite study is to identify scanner errors through central monitoring. This approach has resulted in identification of system errors including sites misidentification of their own gradient hardware and the disabling of autoshim, and a miscalibrated laser alignment light. If undetected, these errors would have contributed to imprecision in quantitative metrics at over 25% of all enrolling ADNI sites.
引用
收藏
页码:2193 / 2205
页数:13
相关论文
共 25 条
[1]   Characterization, prediction, and correction of geometric distortion in 3 T MR images [J].
Baldwin, Lesley N. ;
Wachowicz, Keith ;
Thomas, Steven D. ;
Rivest, Ryan ;
Fallone, B. Gino .
MEDICAL PHYSICS, 2007, 34 (02) :388-399
[2]  
BREEUWER MM, 2001, P SOC PHOTO-OPT INS, V4322, P1120
[3]   Quality assurance of clinical MRI scanners using ACR MRI phantom: Preliminary results [J].
Chen, CC ;
Wan, YL ;
Wai, YY ;
Liu, HL .
JOURNAL OF DIGITAL IMAGING, 2004, 17 (04) :279-284
[4]   Multicenter trial for the set-up of a MRI quality assurance programme [J].
Colombo, P ;
Baldassarri, A ;
Del Corona, M ;
Mascaro, L ;
Strocchi, S .
MAGNETIC RESONANCE IMAGING, 2004, 22 (01) :93-101
[5]   Quality assurance for MRI: practical experience [J].
Firbank, MJ ;
Harrison, RM ;
Williams, ED ;
Coulthard, A .
BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (868) :376-383
[6]   Report on a multicenter fMRI quality assurance protocol [J].
Friedman, L ;
Glover, GH .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 23 (06) :827-839
[7]  
Fu L, 2006, LECT NOTES COMPUT SC, V4191, P144
[8]   Sources and correction of higher order geometrical distortion for serial MR brain imaging [J].
Holden, M ;
Breeuwer, M ;
McLeish, K ;
Hawkes, DJ ;
Keevil, SF ;
Hill, DL .
MEDICAL IMAGING: 2001: IMAGE PROCESSING, PTS 1-3, 2001, 4322 :69-78
[9]   QUALITY ASSESSMENT IN IN-VIVO NMR-SPECTROSCOPY .5. MULTICENTER EVALUATION OF PROTOTYPE TEST OBJECTS AND PROTOCOLS FOR PERFORMANCE ASSESSMENT IN SMALL-BORE MRS EQUIPMENT [J].
HOWE, FA ;
CANESE, R ;
PODO, F ;
VIKHOFF, B ;
SLOTBOOM, J ;
GRIFFITHS, JR ;
HENRIKSEN, O ;
BOVEE, WMMJ .
MAGNETIC RESONANCE IMAGING, 1995, 13 (01) :159-167
[10]   MRI quality control:: six imagers studied using eleven unified image quality parameters [J].
Ihalainen, T ;
Sipilä, O ;
Savolainen, S .
EUROPEAN RADIOLOGY, 2004, 14 (10) :1859-1865