Protein profiling of sickle cell versus control RBC core membrane skeletons by ICAT technology and tandem mass spectrometry

被引:18
作者
Chou, Jose
Choudhary, Pankaj K.
Goodman, Steven R. [1 ]
机构
[1] Univ Texas, Dept Mol & Cell Biol, Richardson, TX USA
[2] Univ Texas, Dept Math Sci, Richardson, TX USA
[3] Univ Texas, Inst Biomed Sci & Technol, Richardson, TX USA
[4] UT SW Med Ctr, Dept Cell Biol, Dallas, TX USA
关键词
proteomics; cleavable ICAT; ion trap mass spectrometry; RBC membrane skeleton; sickle cell;
D O I
10.2478/s11658-006-0026-2
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A proteomic approach using a cleavable ICAT reagent and nano-LC ESI tandem mass spectrometry was used to perforin protein profiling of core RBC membrane skeleton proteins between sickle cell patients (SS) and controls (AA), and determine the efficacy of this technology. The data was validated through Peptide/Protein Prophet and protein ratios were calculated through ASAPratio. Through an ANOVA test, it was determined that there is no significant difference in the mean ratios from control populations (AA1/AA2) and sickle cell versus control populations (AA/SS). The mean ratios were not significantly different from 1.0 in either comparison for the core skeleton proteins (alpha spectrin, beta spectrin, band 4.1 and actin). On the natural-log scale, the variation (standard deviation) of the method was determined to be 14.1% and the variation contributed by the samples was 13.8% which together give a total variation of 19.7% in the ratios.
引用
收藏
页码:326 / 337
页数:12
相关论文
共 26 条
  • [1] Mass spectrometry-based proteomics
    Aebersold, R
    Mann, M
    [J]. NATURE, 2003, 422 (6928) : 198 - 207
  • [2] AN APPROACH TO CORRELATE TANDEM MASS-SPECTRAL DATA OF PEPTIDES WITH AMINO-ACID-SEQUENCES IN A PROTEIN DATABASE
    ENG, JK
    MCCORMACK, AL
    YATES, JR
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (11) : 976 - 989
  • [3] Evaluation of two-dimensional gel electrophoresis-based proteome analysis technology
    Gygi, SP
    Corthals, GL
    Zhang, Y
    Rochon, Y
    Aebersold, R
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2000, 97 (17) : 9390 - 9395
  • [4] Quantitative analysis of complex protein mixtures using isotope-coded affinity tags
    Gygi, SP
    Rist, B
    Gerber, SA
    Turecek, F
    Gelb, MH
    Aebersold, R
    [J]. NATURE BIOTECHNOLOGY, 1999, 17 (10) : 994 - 999
  • [5] Mass spectrometric analysis of protein mixtures at low levels using cleavable 13C-isotope-coded affinity tag and multidimensional chromatography
    Hansen, KC
    Schmitt-Ulms, G
    Chalkley, RJ
    Hirsch, J
    Baldwin, MA
    Burlingame, AL
    [J]. MOLECULAR & CELLULAR PROTEOMICS, 2003, 2 (05) : 299 - 314
  • [6] The human erythrocyte proteome - Analysis by ion trap mass spectrometry
    Kakhniashvili, DG
    Bulla, LA
    Goodman, SR
    [J]. MOLECULAR & CELLULAR PROTEOMICS, 2004, 3 (05) : 501 - 509
  • [7] The proteomics of sickle cell disease: Profiling of erythrocyte membrane proteins by 2D-DIGE and tandem mass spectrometry
    Kakhniashvili, DG
    Griko, NB
    Bulla, LA
    Goodman, SR
    [J]. EXPERIMENTAL BIOLOGY AND MEDICINE, 2005, 230 (11) : 787 - 792
  • [8] Empirical statistical model to estimate the accuracy of peptide identifications made by MS/MS and database search
    Keller, A
    Nesvizhskii, AI
    Kolker, E
    Aebersold, R
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (20) : 5383 - 5392
  • [9] KELLER A, 2003, ISB S
  • [10] LEHMAN EL, 1998, ELEMENTS LARGE SAMPL, P277