Coronary MRA with 3D undersampled projection reconstruction TrueFISP

被引:29
作者
Larson, AC
Simonetti, OP
Li, DB
机构
[1] Northwestern Univ, Dept Biomed Engn, Chicago, IL 60611 USA
[2] Northwestern Univ, Dept Radiol, Chicago, IL 60611 USA
[3] Siemens Med Solut, Iselin, NJ USA
关键词
magnetic resonance imaging (MRI); MR angiography; coronary arteries; projection reconstruction; fast imaging; steady state free precession;
D O I
10.1002/mrm.10262
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Undersampled projection reconstruction (PR) offers improved imaging efficiency allowing a relative tradeoff between signal-to-noise ratio (SNR) or streak artifact and the number of acquired k-space views rather than the tradeoff between resolution or aliasing artifact and the number of acquired k-space lines inherent to Fourier imaging techniques. TrueFISP (true fast imaging with steady state precession) is ideally suited for undersampled PR imaging because of its inherently high SNR. The purpose of this work was to investigate the feasibility of using undersampled three-dimensional (313) PR TrueFISP for breath-hold coronary artery imaging. Phantom studies and a preliminary in vivo comparison demonstrated the improved spatial resolution of PR over Fourier TrueFISP with the same imaging time. In a 24-heartbeat coronary imaging scheme, segmented 313 PR TrueFISP provided a 1.0 x 1.0 mm(2) isotropic in-plane voxel size while acquiring between 93 and 153 views per partition. Streak artifacts were present in some images but were not found to impede coronary artery delineation. In conclusion, 3D undersampled PR TrueFISP provides isotropic in-plane voxel size within a single breathhold and is a promising technique for coronary artery imaging. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:594 / 601
页数:8
相关论文
共 36 条
[1]  
BARGER A, 2000, P 8 ANN M ISMRM DENV, P1513
[2]  
Barger AV, 2000, MAGNET RESON MED, V44, P821, DOI 10.1002/1522-2594(200012)44:6<821::AID-MRM1>3.0.CO
[3]  
2-S
[4]  
Barger AV, 2000, MAGN RESON MED, V43, P503, DOI 10.1002/(SICI)1522-2594(200004)43:4<503::AID-MRM3>3.0.CO
[5]  
2-0
[6]  
BLOCK WF, 2000, P 8 ISMRM SCI M DENV, P161
[7]  
Botnar RM, 2000, JMRI-J MAGN RESON IM, V11, P389, DOI 10.1002/(SICI)1522-2586(200004)11:4<389::AID-JMRI6>3.0.CO
[8]  
2-T
[9]   Cine MR angiography of the heart with segmented true fast imaging with steady-state precession [J].
Carr, JC ;
Simonetti, O ;
Bundy, J ;
Li, DB ;
Pereles, S ;
Finn, JP .
RADIOLOGY, 2001, 219 (03) :828-834
[10]   Breath-hold three-dimensional true-FISP imaging of coronary arteries using asymmetric sampling [J].
Deshpande, VS ;
Shea, SM ;
Chung, YC ;
McCarthy, RM ;
Finn, JP ;
Li, DB .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 15 (04) :473-478