Search for the Optimal Right Ventricular Pacing Site: Design and Implementation of Three Randomized Multicenter Clinical Trials

被引:48
作者
Kaye, Gerry [2 ]
Stambler, Bruce S. [1 ]
Yee, Raymond [3 ]
机构
[1] Univ Hosp Cleveland, Div Cardiol, Case Med Ctr, Cleveland, OH 44106 USA
[2] Univ Queensland, Brisbane, Qld, Australia
[3] Univ Hosp, London, ON, Canada
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2009年 / 32卷 / 04期
关键词
ventricular pacing; septal pacing; left ventricular function; dyssynchrony; CONGESTIVE-HEART-FAILURE; OUTFLOW-TRACT; APEX; ACTIVATION; PERFUSION; ABLATION; LEAD;
D O I
10.1111/j.1540-8159.2009.02301.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The optimal site to permanently pace the right ventricle (RV) has yet to be determined. To address this issue, three randomized prospective multicenter clinical trials are in progress comparing the long-term effects of RV apical versus septal pacing on left ventricular (LV) function. The three trials are Optimize RV Selective Site Pacing Clinical Trial (Optimize RV), Right Ventricular Apical and High Septal Pacing to Preserve Left Ventricular Function (Protect Pace), and Right Ventricular Apical versus Septal Pacing (RASP). Methods: Patients that require frequent or continuous ventricular pacing are randomized to RV apical or septal pacing. Optimize RV excludes patients with LV ejection fraction < 40% prior to implantation, whereas the other trials include patients regardless of baseline LV systolic function. The RV septal lead is positioned in the mid-septum in Optimize RV, the high septum in Protect Pace, and the mid-septal inflow tract in RASP. Lead position is confirmed by fluoroscopy in two planes and adjudicated by a blinded panel. The combined trials will follow approximately 800 patients for up to 3 years. Results: The primary outcome in each trial is LV ejection fraction evaluated by radionuclide ventriculography or echocardiography. Secondary outcomes include echo-based measurements of ventricular/atrial remodeling, 6-minute hall walk distance, brain natriuretic peptide levels, and clinical events (atrial tachyarrhythmias, heart failure, stroke, or death). Conclusion: These selective site ventricular pacing trials should provide evidence of the importance of RV pacing site in the long-term preservation of LV function in patients that require ventricular pacing and help to clarify the optimal RV pacing site. (PACE 2009; 32: 426-433)
引用
收藏
页码:426 / 433
页数:8
相关论文
共 35 条
[1]   MYOFIBRILLAR DISARRAY PRODUCED IN NORMAL HEARTS BY CHRONIC ELECTRICAL PACING [J].
ADOMIAN, GE ;
BEAZELL, J .
AMERICAN HEART JOURNAL, 1986, 112 (01) :79-83
[2]  
Blanc JJ, 1997, CIRCULATION, V96, P3273
[3]   Evolution of ventricular function during permanent pacing from either right ventricular apex or outflow tract following AV-junctional ablation for atrial fibrillation [J].
Bourke, JP ;
Hawkins, T ;
Keavey, P ;
Tynan, M ;
Jamieson, S ;
Behulova, R ;
Furniss, SS .
EUROPACE, 2002, 4 (03) :219-228
[4]   Systolic and diastolic function with alternate and combined site pacing in the right ventricle [J].
Buckingham, TA ;
Candinas, R ;
Attenhofer, C ;
Van Hoeven, H ;
Hug, R ;
Hess, O ;
Jenni, R ;
Amann, FW .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (05) :1077-1084
[5]   INFLUENCE OF PACING SITE ON CANINE LEFT-VENTRICULAR CONTRACTION [J].
BURKHOFF, D ;
OIKAWA, RY ;
SAGAWA, K .
AMERICAN JOURNAL OF PHYSIOLOGY, 1986, 251 (02) :H428-H435
[6]   Comparison of the haemodynamic effects of right ventricular outflow-tract pacing with right ventricular apex pacing - A quantitative review [J].
de Cock, CC ;
Giudici, MC ;
Twisk, JV .
EUROPACE, 2003, 5 (03) :275-278
[7]  
de Cock CC, 1998, PACE, V21, P536, DOI 10.1111/j.1540-8159.1998.tb00095.x
[8]   TOTAL EXCITATION OF ISOLATED HUMAN HEART [J].
DURRER, D ;
VANDAM, RT ;
FREUD, GE ;
JANSE, MJ ;
MEIJLER, FL ;
ARZBAECHER, RC .
CIRCULATION, 1970, 41 (06) :899-+
[9]   Multi-center clinical experience with a lumenless, catheter-delivered, bipolar, permanent pacemaker lead: Implant safety and electrical performance [J].
Gammage, Michael D. ;
Lieberman, Randy A. ;
Yee, Raymond ;
Manolis, Antonis S. ;
Compton, Steven J. ;
Khazen, Cesar ;
Schaaf, Katie ;
Oleson, Kimberly A. ;
Crossley, George H. .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2006, 29 (08) :858-865
[10]   Comparison of right ventricular outflow tract and apical lead permanent pacing on cardiac output [J].
Giudici, MC ;
Thornburg, GA ;
Buck, DAL ;
Coyne, EP ;
Walton, MC ;
Paul, DL ;
Sutton, J .
AMERICAN JOURNAL OF CARDIOLOGY, 1997, 79 (02) :209-&