Capillary electrophoretic separations of proteins using carrier ampholytes

被引:21
作者
Chartogne, A [1 ]
Reeuwijk, B [1 ]
Hofte, B [1 ]
van der Heijden, R [1 ]
Tjaden, UR [1 ]
van der Greef, J [1 ]
机构
[1] Gorlaeus Labs, Leiden Amsterdam Ctr Drug Res, Div Analyt Chem, NL-2300 RA Leiden, Netherlands
关键词
ampholytes; isoelectric focusing; isotachophoresis; proteins;
D O I
10.1016/S0021-9673(02)00450-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Capillary separations of proteins using carrier ampholytes are performed between an anolyte and a catholyte of same pH (pH 3). Depending upon the concentration of carrier ampholytes used, two different separation processes take place. At a 10% concentration, the high-resolution separation of six model proteins is achieved, which can be described as a transient capillary isoelectric focusing (cIEF) system moving isotachophoretically. The isotachophoretic (ITP) behaviour of the system is evidenced by the influence of the catholyte concentration on the separation. The separation is neither pure cIEF nor pure cITP and the migration order of the proteins results from the influence of both their isolelectric points and their mobilities. (C) 2002 Published by Elsevier Science B.V.
引用
收藏
页码:289 / 298
页数:10
相关论文
共 19 条
[1]   ISOTACHOPHORESIS OF PROTEINS [J].
ACEVEDO, F .
JOURNAL OF CHROMATOGRAPHY, 1989, 470 (02) :407-414
[2]   ISOTACHOPHORESIS - QUALITATIVE SEPARATION OF CATION MIXTURES [J].
BECKERS, JL ;
EVERAERT.FM .
JOURNAL OF CHROMATOGRAPHY, 1972, 68 (01) :207-&
[3]   ISOTACHOPHORETIC FOCUSING ON THIN GEL SLAB - A NEW AND POWERFUL ELECTROPHORETIC METHOD OF PROTEIN-ANALYSIS [J].
CHARLIONET, R ;
BRINGARD, A ;
DAVRINCHE, C ;
FONTAINE, M .
ELECTROPHORESIS, 1986, 7 (12) :558-566
[4]   ANALYTICAL ISOTACHOPHORESIS [J].
EVERAERTS, FM ;
GEURTS, M ;
MIKKERS, FEP ;
VERHEGGEN, PEM .
JOURNAL OF CHROMATOGRAPHY, 1976, 119 (APR28) :129-155
[5]  
EVERAERTS FM, 1976, ISOTACHOPHORESIS, P13
[6]  
EVERAERTS FM, 1976, ISOTACHOPHORESIS, P322
[7]   HIGH-PERFORMANCE ELECTROPHORESIS - ELIMINATION OF ELECTROENDOSMOSIS AND SOLUTE ADSORPTION [J].
HJERTEN, S .
JOURNAL OF CHROMATOGRAPHY, 1985, 347 (02) :191-198
[8]   ADAPTATION OF THE EQUIPMENT FOR HIGH-PERFORMANCE ELECTROPHORESIS TO ISOELECTRIC-FOCUSING [J].
HJERTEN, S ;
ZHU, MD .
JOURNAL OF CHROMATOGRAPHY, 1985, 346 (OCT) :265-270
[9]   HIGH-PERFORMANCE DISPLACEMENT ELECTROPHORESIS IN 0.025-MM TO 0.050-MM CAPILLARIES COATED WITH A POLYMER TO SUPPRESS ADSORPTION AND ELECTROENDOSMOSIS [J].
HJERTEN, S ;
KIESSLINGJOHANSSON, M .
JOURNAL OF CHROMATOGRAPHY, 1991, 550 (1-2) :811-822
[10]   Capillary isotachophoretic analysis of serum lipoproteins using a carrier ampholyte as spacer ion [J].
Inano, K ;
Tezuka, S ;
Miida, T ;
Okada, M .
ANNALS OF CLINICAL BIOCHEMISTRY, 2000, 37 :708-716