The delivery rate accuracy of portable infusion pumps used for continuous regional analgesia

被引:43
作者
Ilfeld, BM
Morey, TE
Enneking, FK
机构
[1] Univ Florida, Coll Med, Dept Anesthesiol, Gainesville, FL 32610 USA
[2] Univ Florida, Coll Med, Dept Orthopaed & Rehabil, Gainesville, FL 32610 USA
关键词
D O I
10.1097/00000539-200211000-00043
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Portable pumps used for local anesthetic infusion during continuous regional analgesia are gaining acceptance. These pumps are often used for ambulatory patients who are medically unsupervised throughout most of the infusion. However, the performance of these pumps, which infuse potentially toxic medication, has not been independently investigated. We investigated the flow rate accuracy, consistency, and profiles of various portable pumps often used for local anesthetic infusion during continuous regional analgesia. By using a computer/scale combination within a laboratory to record infusion rates, 6 pumps were tested with their flow regulators at expected (30degrees-32degreesC) and increased (34degrees-36degreesC) temperatures. Infusion rate accuracy differed significantly among the pumps, exhibiting flow rates within +/- 15% of their expected rate for 18%-100% of their infusion duration. An increase in temperature also affected pumps to differing degrees, with infusion rates increasing from 0% to 25% for each model tested. These results suggest that factors such as flow rate accuracy and consistency, infusion profile, and temperature sensitivity should be considered when choosing and using a portable infusion pump for local anesthetic administration.
引用
收藏
页码:1331 / 1336
页数:6
相关论文
共 10 条
[1]   A METHOD OF CONTINUOUS BRACHIAL PLEXUS BLOCK [J].
ANSBRO, FP .
AMERICAN JOURNAL OF SURGERY, 1946, 71 (06) :716-722
[2]   Elastomeric pumps for ambulatory patient controlled regional analgesia. [J].
Ganapathy, S ;
Amendola, A ;
Lichfield, R ;
Fowler, PJ ;
Ling, E .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2000, 47 (09) :897-902
[3]   A portable mechanical pump providing over four days of patient-controlled analgesia by perineural infusion at home [J].
Ilfeld, BM ;
Enneking, FK .
REGIONAL ANESTHESIA AND PAIN MEDICINE, 2002, 27 (01) :100-104
[4]   Major ambulatory surgery with continuous regional anesthesia and a disposable infusion pump [J].
Klein, SM ;
Greengrass, RA ;
Gleason, DH ;
Nunley, JA ;
Steele, SM .
ANESTHESIOLOGY, 1999, 91 (02) :563-565
[5]   Interscalene brachial plexus block with continuous intraarticular infusion of ropivacaine [J].
Klein, SM ;
Nielsen, KC ;
Martin, A ;
White, W ;
Warner, DS ;
Steele, SM ;
Speer, KP ;
Greengrass, RA .
ANESTHESIA AND ANALGESIA, 2001, 93 (03) :601-605
[6]   Interscalene brachial plexus block with a continuous catheter insertion system and a disposable infusion pump [J].
Klein, SM ;
Grant, SA ;
Greengrass, RA ;
Nielsen, KC ;
Speer, KP ;
White, W ;
Warner, DS ;
Steele, SM .
ANESTHESIA AND ANALGESIA, 2000, 91 (06) :1473-1478
[7]   PATIENT-CONTROLLED ANALGESIA USING A MINIATURE ELECTROCHEMICALLY DRIVEN INFUSION-PUMP [J].
OKEEFE, D ;
OHERLIHY, C ;
GROSS, Y ;
KELLY, JG .
BRITISH JOURNAL OF ANAESTHESIA, 1994, 73 (06) :843-846
[8]   Postoperative patient-controlled local anesthetic administration at home [J].
Rawal, N ;
Axelsson, AK ;
Hylander, J ;
Allvin, R ;
Amilon, A ;
Lidegran, G ;
Hallén, J .
ANESTHESIA AND ANALGESIA, 1998, 86 (01) :86-89
[9]   EVALUATION OF A DISPOSABLE, ELASTOMERIC INFUSION DEVICE IN THE HOME-ENVIRONMENT [J].
RICH, DS .
AMERICAN JOURNAL OF HOSPITAL PHARMACY, 1992, 49 (07) :1712-1716
[10]   The pain control infusion pump for postoperative pain control in shoulder surgery [J].
Savoie, FH ;
Field, LD ;
Jenkins, RN ;
Mallon, WJ ;
Phelps, RA .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2000, 16 (04) :339-342