Precision and accuracy of acoustospectrographic parameters

被引:47
作者
Huisman, HJ
Thijssen, JM
机构
[1] UNIV HOSP,CLIN PHYS LAB,DEPT PEDIAT,NL-6500 HB NIJMEGEN,NETHERLANDS
[2] UNIV HOSP,BIOPHYS LAB,DEPT OPHTHALMOL,NL-6500 HB NIJMEGEN,NETHERLANDS
关键词
tissue characterization; attenuation; backscatter; precision; accuracy; diffraction correction; inter- and intrasubject variability;
D O I
10.1016/0301-5629(96)00105-6
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Theoretical estimates of the standard deviation (STD) of four acoustospectrographic parameters (the intercept and slope of attenuation and backscatter coefficient) are derived. This derivation expands and corrects existing derivations, and is confirmed using simulations based on the adopted theoretical model. A robust parameter estimation method is applied to various phantom measurements, and to in vivo liver scans of healthy human subjects. The measured STD is higher than the theoretically predicted value, and we investigated four possible factors which explain this discrepancy. First, it is shown that the STD and bias after spectrogram calculation are rather insensitive to changes in windowing function, type, length and overlap. Second, we observed that a diffraction correction spectrogram calibrated on a medium different from the one being measured insufficiently corrects the depth-dependency of the parameters, which affects both precision as well as accuracy. We therefore propose a method that constructs an organ-specific diffraction correction spectrogram from the averaged spectrogram of a set of normal organs. We show that the organ-specific correction does not affect STD even in case of previously unseen acquisitions. Third, we introduce local inhomogeneity, which predicts excess STD due to local variations of the physical parameters within an organ (i.e., intrasubject), and global inhomogeneity, which predicts variations between organs (i.e., intersubject). We conclude that our method of estimating STD predicts normal, in vivo data very well, and propose that the deviation from these estimates is a potential tissue characterization parameter.
引用
收藏
页码:855 / 871
页数:17
相关论文
共 37 条
[1]   THE EFFECT OF WINDOWING ON SPECTRAL ESTIMATION OF ECHOES SCATTERED BY A RANDOM MEDIUM [J].
AKITA, M ;
UEDA, M .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1988, 83 (04) :1243-1248
[2]  
[Anonymous], 1976, IEEE ULTRASONICS S P, V44, P44
[3]   OPTIMAL PRECISION IN ULTRASOUND ATTENUATION ESTIMATION AND APPLICATION TO THE DETECTION OF DUCHENNE MUSCULAR-DYSTROPHY CARRIERS [J].
BERGER, G ;
LAUGIER, P ;
FINK, M ;
PERRIN, J .
ULTRASONIC IMAGING, 1987, 9 (01) :1-17
[4]   Simulation of ultrasonic imaging with linear arrays in causal absorptive media [J].
Berkhoff, AP ;
Thijssen, JM ;
Homan, RJF .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1996, 22 (02) :245-259
[5]   SPECKLE IN ULTRASOUND B-MODE SCANS [J].
BURCKHARDT, CB .
IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1978, 25 (01) :1-6
[6]   DIFFRACTION CORRECTION METHODS FOR PULSE-ECHO ACOUSTIC ATTENUATION ESTIMATION [J].
CESPEDES, I ;
OPHIR, J .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1990, 16 (07) :707-717
[7]   A BEAM CORRECTED ESTIMATION OF THE FREQUENCY-DEPENDENT ATTENUATION OF BIOLOGICAL TISSUES FROM BACKSCATTERED ULTRASOUND [J].
CLOOSTERMANS, MJTM ;
THIJSSEN, JM .
ULTRASONIC IMAGING, 1983, 5 (02) :136-147
[8]   ULTRASONIC SIGNAL-PROCESSING FOR INVIVO ATTENUATION MEASUREMENT - SHORT-TIME FOURIER-ANALYSIS [J].
FINK, M ;
HOTTIER, F ;
CARDOSO, JF .
ULTRASONIC IMAGING, 1983, 5 (02) :117-135
[9]  
Goodman J. W., 1975, LASER SPECKLE RELATE, P9, DOI [DOI 10.1088/0335-7368/6/1/301, 10.1007/bfb0111436, DOI 10.1007/978-3-662-43205-1_2]
[10]   IMPROVEMENTS IN THE SPECTRAL DIFFERENCE METHOD FOR MEASURING ULTRASONIC-ATTENUATION [J].
INSANA, M ;
ZAGZEBSKI, J ;
MADSEN, E .