Spectra and air-kerma strength for encapsulated 192Ir sources

被引:73
作者
Borg, J [1 ]
Rogers, DWO [1 ]
机构
[1] Natl Res Council Canada, Inst Natl Measurement Stand, Ottawa, ON K1A 0R6, Canada
关键词
Ir-192; brachytherapy sources; fluence spectra; air-kerma strength; Monte Carlo; EGS4;
D O I
10.1118/1.598763
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The photon spectra in vacuum around four types of Ir-192 HDR brachytherapy sources are calculated using the Monte Carlo code EGS4 and the most recent spectral information on Ir-192 decay. The air-kerma strengths per unit activity are calculated based on the photon fluence around a bare Ir-192 source and around each of four types of encapsulated sources using recent mass energy-absorption coefficients. For the full spectrum the bare vs encapsulated difference is up to 23% due to the large air-kerma contribution from the unfiltered low-energy photons. For the penetrating part of the photon spectrum (>11.3 keV), the air-kerma strength per unit source activity on the transverse axis for a bare source is 2-15% higher than for the encapsulated sources due to the attenuation and absorption in the core and the encapsulating material. The contribution to the air-kerma strength from photons scattered in the capsule and from bremsstrahlung are calculated to increase the air-kerma strength by 2-4% and 0.2-0.3%, respectively. Air-kerma strengths for a variety of sources agree well with previously reported results for sources from Nucletron International, Best Industries, Inc., and Alpha-Omega Services, Inc. In addition we present air-kerma strengths for the present model of the HDR source from Nucletron International and the source from Varian Associates, Inc. [S0094-2405(99)00211-4].
引用
收藏
页码:2441 / 2444
页数:4
相关论文
共 16 条
[1]  
*AAPM, 1987, TG32 AAPM
[2]  
BIELAJEW AF, 1986, PIRS0042 NAT RES COU
[3]  
Borg J., 1998, PIRS629R NRC, DOI DOI 10.4224/5764262
[4]   ACTIVITY DETERMINATION OF IR-192 SOLID SOURCES BY IONIZATION-CHAMBER MEASUREMENTS USING CALCULATED CORRECTIONS FOR SELF-ABSORPTION [J].
BUERMANN, L ;
KRAMER, HM ;
SCHRADER, H ;
SELBACH, HJ .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 339 (1-2) :369-376
[5]  
Duchemin B., 1993, LPRI93018 DAMRI CEA
[6]  
GLASGOW G P, 1979, Medical Physics (Woodbury), V6, P49, DOI 10.1118/1.594551
[7]   CALIBRATION OF IR-192 HIGH-DOSE-RATE AFTERLOADING SYSTEMS [J].
GOETSCH, SJ ;
ATTIX, FH ;
PEARSON, DW ;
THOMADSEN, BR .
MEDICAL PHYSICS, 1991, 18 (03) :462-467
[8]  
Hubbell JH, 1995, TECHNICAL REPORT
[9]   DOSIMETRY OF INTERSTITIAL BRACHYTHERAPY SOURCES - RECOMMENDATIONS OF THE AAPM RADIATION-THERAPY COMMITTEE TASK GROUP NO 43 [J].
NATH, R ;
ANDERSON, LL ;
LUXTON, G ;
WEAVER, KA ;
WILLIAMSON, JF ;
MEIGOONI, AS .
MEDICAL PHYSICS, 1995, 22 (02) :209-234
[10]  
Nelson W., 1985, SLAC265