Analysis of a low-finesse Fabry-Perot sensing interferometer illuminated by a multimode optical fiber

被引:28
作者
Pérennès, F
Beard, PC
Mills, TN
机构
[1] UCL, Dept Med Phys & Bioengn, London WC1E 6JA, England
[2] Sincrotrone Trieste, Expt Div Area Sci Pk, I-34012 Trieste, Italy
关键词
D O I
10.1364/AO.38.007026
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A model of the reflected fringe system for an ideal plane-parallel, low-finesse Fabry-Perot (FP) cavity illuminated by a multimode optical fiber has been developed and experimentally validated. This showed that the phase dispersion within the cavity arising from the divergent nature of the incident illumination significantly degrades the visibility of the reflected fringes. Departures fr-om the ideal FP cavity are also examined. The effect on fringe visibility when the plane of the FP cavity is tilted with respect to the fiber axis and when the cavity surfaces are no longer perfectly parallel to each other has been explored. The analysis described is relevant to the design and the optimization of multimode optical-fiber sensors that use FP sensing cavities. (C) 1999 Optical Society of America OCIS codes: 060.2370, 120.2230.
引用
收藏
页码:7026 / 7034
页数:9
相关论文
共 13 条
[1]   Analysis of the effect of imperfect fiber endfaces on the performance of extrinsic Fabry-Perot interferometric optical fiber sensors [J].
Arya, V ;
deVries, MJ ;
Athreya, M ;
Wang, AB ;
Claus, RO .
OPTICAL ENGINEERING, 1996, 35 (08) :2262-2265
[2]  
Arya V., 1995, Optical Fiber Technology: Materials, Devices and Systems, V1, P380, DOI 10.1006/ofte.1995.1037
[3]   Extrinsic optical-fiber ultrasound sensor using a thin polymer film as a low-finesse Fabry-Perot interferometer [J].
Beard, PC ;
Mills, TN .
APPLIED OPTICS, 1996, 35 (04) :663-675
[4]   Miniature optical fibre ultrasonic hydrophone using a Fabry-Perot polymer film interferometer [J].
Beard, PC ;
Mills, TN .
ELECTRONICS LETTERS, 1997, 33 (09) :801-803
[5]   Optical fiber photoacoustic-photothermal probe [J].
Beard, PC ;
Perennes, F ;
Draguioti, E ;
Mills, TN .
OPTICS LETTERS, 1998, 23 (15) :1235-1237
[6]   Acoustic performance and clinical use of a fibreoptic hydrophone [J].
Coleman, AJ ;
Draguioti, E ;
Tiptaf, R ;
Shotri, N ;
Saunders, JE .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (01) :143-151
[7]  
COX ER, 1983, P 1 INT C OPT FIB SE, P122
[8]  
HECHT E, 1987, OPTICS, P364
[9]   A multi-mode extrinsic Fabry-Perot interferometric strain sensor [J].
Liu, T ;
Brooks, D ;
Martin, A ;
Badcock, R ;
Ralph, B ;
Fernando, GF .
SMART MATERIALS & STRUCTURES, 1997, 6 (04) :464-469
[10]   QUADRATURE PHASE-SHIFTED, EXTRINSIC FABRY-PEROT OPTICAL FIBER SENSORS [J].
MURPHY, KA ;
GUNTHER, MF ;
VENGSARKAR, AM ;
CLAUS, RO .
OPTICS LETTERS, 1991, 16 (04) :273-275