Asymptomatic recurrences of atrial fibrillation after pulmonary vein isolation

被引:28
作者
Neumann, Thomas [1 ]
Erdogan, Ali [1 ]
Dill, Thorsten [1 ]
Greiss, Harald [1 ]
Berkowitsch, Alexander [1 ]
Sperzel, Johannes [1 ]
Kuniss, Malte [1 ]
Kurzidim, Klaus [1 ]
Hamm, Christian W. [1 ]
Pitschner, Heinz-Friedrich [1 ]
机构
[1] Kerckhoff Heart Ctr, Dept Cardiol, Bad Nauheim, Germany
来源
EUROPACE | 2006年 / 8卷 / 07期
关键词
catheter ablation; event recording; atrial fibrillation;
D O I
10.1093/europace/eul056
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims The purpose of this study was to determine the occurrence of asymptomatic episodes of atrial fibrillation (AF) and wrong AF perception after pulmonary vein isolation (PVI). We evaluated the success of ablation by using the following measurements: (i) clinical symptoms and duration of symptoms noticed by patients and (ii) synchronous event recording (ER). Methods and results Eighty patients with paroxysmal AF underwent PVI and were provided repeatedly with a portable ER upon discharge and every 3 months for a year. The ER automatically detects arrhythmias by a detection algorithm and can also be manually triggered by the patient. In 46/80 patients (57.5%), episodes of AF were documented. Asymptomatic AF was detected in 21.3%. In 9/80 patients (11.3%), who reported clinical AF recurrence, no AF could be shown by ER. We compared patients' perception to have suffered AF episodes with the ERs and found a sensitivity of 75% and a specificity of 92%. Conclusion Reliance on perception of AF by patients after PVI results in an underestimation of recurrence of the arrhythmia. We observed a maximal occurrence of silent AF or wrong perception of AF in 26/80 (32.6%) patients.
引用
收藏
页码:495 / 498
页数:4
相关论文
共 16 条
[1]   INDEPENDENT RISK-FACTORS FOR ATRIAL-FIBRILLATION IN A POPULATION-BASED COHORT - THE FRAMINGHAM HEART-STUDY [J].
BENJAMIN, EJ ;
LEVY, D ;
VAZIRI, SM ;
DAGOSTINO, RB ;
BELANGER, AJ ;
WOLF, PA .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1994, 271 (11) :840-844
[2]   Effect of radiofrequency catheter ablation an health-related quality of life and activities of daily living in patients with recurrent arrhythmias [J].
Bubien, RS ;
KnottsDolson, SM ;
Plumb, VJ ;
Kay, GN .
CIRCULATION, 1996, 94 (07) :1585-1591
[3]   Initiation of atrial fibrillation by ectopic beats originating from the pulmonary veins - Electrophysiological characteristics, pharmacological responses, and effects of radiofrequency ablation [J].
Chen, SA ;
Hsieh, MH ;
Tai, CT ;
Tsai, CF ;
Prakash, VS ;
Yu, WC ;
Hsu, TL ;
Ding, YA ;
Chang, MS .
CIRCULATION, 1999, 100 (18) :1879-1886
[4]   Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins [J].
Haïssaguerre, M ;
Jaïs, P ;
Shah, DC ;
Takahashi, A ;
Hocini, M ;
Quiniou, G ;
Garrigue, S ;
Le Mouroux, A ;
Le Métayer, P ;
Clémenty, J .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (10) :659-666
[5]   Perception of atrial fibrillation before and after radiofrequency catheter ablation - Relevance of asymptomatic arrhythmia recurrence [J].
Hindricks, G ;
Piorkowski, C ;
Tanner, H ;
Kobza, R ;
Gerds-Li, JH ;
Carbucicchio, C ;
Kottkamp, H .
CIRCULATION, 2005, 112 (03) :307-313
[6]   Ablation therapy for atrial fibrillation (AF):: Past, present and future [J].
Jaïs, P ;
Weerasooriya, R ;
Shah, DC ;
Hocini, M ;
Macle, L ;
Choi, KJ ;
Scavee, C ;
Haïssaguerre, M ;
Clémenty, J .
CARDIOVASCULAR RESEARCH, 2002, 54 (02) :337-346
[7]   Follow-up of atrial fibrillation: The initial experience of the Canadian registry of atrial fibrillation [J].
Kerr, C ;
Boone, J ;
Connolly, S ;
Greene, M ;
Klein, G ;
Sheldon, R ;
Talajic, M .
EUROPEAN HEART JOURNAL, 1996, 17 :48-51
[8]   Cardiac event recorders yield more diagnoses and are more cost-effective than 48-hour holter monitoring in patients with palpitations - A controlled clinical trial [J].
Kinlay, S ;
Leitch, JW ;
Neil, A ;
Chapman, BL ;
Hardy, DB ;
Fletcher, PJ .
ANNALS OF INTERNAL MEDICINE, 1996, 124 (01) :16-20
[9]   Circular mapping and ablation of the pulmonary vein for treatment of atrial fibrillation - Impact of different catheter technologies [J].
Marrouche, NF ;
Dresing, T ;
Cole, C ;
Bash, D ;
Saad, E ;
Balaban, K ;
Pavia, SV ;
Schweikert, R ;
Saliba, W ;
Abdul-Karim, A ;
Pisano, E ;
Fanelli, R ;
Tchou, P ;
Natale, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 40 (03) :464-474
[10]   Pulmonary vein isolation for paroxysmal and persistent atrial fibrillation [J].
Oral, H ;
Knight, BP ;
Tada, H ;
Özaydin, M ;
Chugh, A ;
Hassan, S ;
Scharf, C ;
Lai, SWK ;
Greenstein, R ;
Pelosi, F ;
Strickberger, SA ;
Morady, F .
CIRCULATION, 2002, 105 (09) :1077-1081