Influence of age on hypnotic requirement, bispectral index, and 95% spectral edge frequency associated with sedation induced by sevoflurane

被引:66
作者
Katoh, T [1 ]
Bito, H [1 ]
Sato, S [1 ]
机构
[1] Hamamatsu Univ Sch Med, Dept Anesthesiol & Intens Care, Hamamatsu, Shizuoka 4313192, Japan
关键词
anesthetic potency; gender; prediction probability;
D O I
10.1097/00000542-200001000-00014
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Aging is associated with a reduction in anesthetic requirements. The effects of age on the electroencephalographic response to inhalational anesthesia have not been well documented. The objective of the present study was to determine the influence of age on hypnotic requirement and electroencephalographic derivatives such as bispectral index and 95% spectral edge frequency associated with sedation induced by sevoflurane. Methods: Ninety-six patients were randomly allocated into one of three age groups A, B, and C, ranging in age from 18-39 yr, 40-64 yr, and 65-85 yr, respectively. Patients in each group were sedated with sevoflurane at two predetermined concentrations ranging between 0.45% and 0.85%. The relationship between sevoflurane concentration and response to a verbal command, as well as the relationships between response and bispectral index and 95% spectral edge frequency, was determined. Results: Multiple regression analysis showed that end-tidal sevoflurane concentration and age significantly affected both bispectral index and 95% spectral edge frequency, ED,, values of sevoflurane concentration for loss of consciousness, defined as no response to verbal command, were different between groups A and C: 0.72 (95% confidence interval: 0.68-0.75) versus 0.59 (95% confidence interval: 0.56-0.62). However, the same effective values of bispectral index and 95% spectral edge frequency at this same clinical end point did not differ. Conclusions: Increasing age reduced sevoflurane requirements to suppress responses to a verbal command but did not change bispectral index and 95% spectral edge frequency associated with this end point, and in a population with a wide age range, bispectral index would predict depth of sedation better than end-tidal sevoflurane concentration.
引用
收藏
页码:55 / 61
页数:7
相关论文
共 36 条
[1]   EXAGGERATED ANESTHETIC REQUIREMENTS IN THE PREFERENTIALLY ANESTHETIZED BRAIN [J].
ANTOGNINI, JF ;
SCHWARTZ, K .
ANESTHESIOLOGY, 1993, 79 (06) :1244-1249
[2]   PLASMA-CONCENTRATIONS OF ALFENTANIL REQUIRED TO SUPPLEMENT NITROUS-OXIDE ANESTHESIA FOR GENERAL-SURGERY [J].
AUSEMS, ME ;
HUG, CC ;
STANSKI, DR ;
BURM, AGL .
ANESTHESIOLOGY, 1986, 65 (04) :362-373
[3]  
CHERNIK DA, 1990, J CLIN PSYCHOPHARM, V10, P244
[4]   Relationship between calculated blood concentration of propofol and electrophysiological variables during emergence from anaesthesia: Comparison of bispectral index, spectral edge frequency, median frequency and auditory evoked potential index [J].
Doi, M ;
Gajraj, RJ ;
Mantzaridis, H ;
Kenny, GNC .
BRITISH JOURNAL OF ANAESTHESIA, 1997, 78 (02) :180-184
[5]   THE ELECTROENCEPHALOGRAM DOES NOT PREDICT DEPTH OF ISOFLURANE ANESTHESIA [J].
DWYER, RC ;
RAMPIL, IJ ;
EGER, EI ;
BENNETT, HL .
ANESTHESIOLOGY, 1994, 81 (02) :403-409
[6]   Bispectral analysis measures sedation and memory effects of propofol, midazolam, isoflurane, and alfentanil in healthy volunteers [J].
Glass, PS ;
Bloom, M ;
Kearse, L ;
Rosow, C ;
Sebel, P ;
Manberg, P .
ANESTHESIOLOGY, 1997, 86 (04) :836-847
[7]  
GOLD MI, 1993, ANESTHESIOLOGY, V79, P710
[8]   THE EFFECT OF INCREASING AGE ON THIOPENTAL DISPOSITION AND ANESTHETIC REQUIREMENT [J].
HOMER, TD ;
STANSKI, DR .
ANESTHESIOLOGY, 1985, 62 (06) :714-724
[9]  
Kasamatsu T, 1981, Sangyo Igaku, V23, P127
[10]   The effects of fentanyl on sevoflurane requirements for loss of consciousness and skin incision [J].
Katoh, T ;
Ikeda, K .
ANESTHESIOLOGY, 1998, 88 (01) :18-24