A three-dimensional digital image correlation technique for strain measurements in microstructures

被引:229
作者
Verhulp, E [1 ]
van Rietbergen, B [1 ]
Huiskes, R [1 ]
机构
[1] Eindhoven Univ Technol, Dept Biomed Engn, NL-5600 MB Eindhoven, Netherlands
关键词
strain measurements; trabecular bone; image correlation; computed tomography;
D O I
10.1016/j.jbiomech.2003.12.036
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A three-dimensional digital image correlation technique is presented for strain measurements in open-cell structures such as trabecular bone. The technique uses high-resolution computed tomography images for displacement measurements in the solid structure. In order to determine the local strain-state within single trabeculae, a tetrahedronization method is used to fill the solid structure with tetrahedrae. Displacements are calculated at the nodes of the tetrahedrae. The displacement data is subsequently converted to a deformation tensor in each of the tetrahedral element centers with a least-squares estimation method. Because the trabeculae are represented by a mesh, it is possible to deform this mesh according to the deformation tensor and, at the same time, visualize the calculated local strain in the deformed mesh with a finite element post-processing tool. In this way, the deformation of a single trabecula from an aluminum foam sample was determined and validated with rendered images of the three-dimensional sample. A precision analysis showed that a rigid translation or rotation does not affect the accuracy. Typical values for the standard deviation in the displacement and strain components are 2.0 mum and 0.01, respectively. Presently, the precision limits the technique to strain measurements beyond the yield strain. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1313 / 1320
页数:8
相关论文
共 26 条
[1]   Digital volume correlation: Three-dimensional strain mapping using X-ray tomography [J].
Bay, BK ;
Smith, TS ;
Fyhrie, DP ;
Saad, M .
EXPERIMENTAL MECHANICS, 1999, 39 (03) :217-226
[2]   TEXTURE CORRELATION - A METHOD FOR THE MEASUREMENT OF DETAILED STRAIN DISTRIBUTIONS WITHIN TRABECULAR BONE [J].
BAY, BK .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1995, 13 (02) :258-267
[3]   CONTRIBUTION OF COLLAGEN AND MINERAL TO ELASTIC-PLASTIC PROPERTIES OF BONE [J].
BURSTEIN, AH ;
ZIKA, JM ;
HEIPLE, KG ;
KLEIN, L .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1975, 57 (07) :956-961
[4]   A COMPARISON OF THE FATIGUE BEHAVIOR OF HUMAN TRABECULAR AND CORTICAL BONE TISSUE [J].
CHOI, K ;
GOLDSTEIN, SA .
JOURNAL OF BIOMECHANICS, 1992, 25 (12) :1371-1381
[5]   High strain rate compression of closed-cell aluminium foams [J].
Dannemann, KA ;
Lankford, J .
MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2000, 293 (1-2) :157-164
[6]   FULLY-AUTOMATIC MESH GENERATION FOR 3-D DOMAINS BASED UPON VOXEL SETS [J].
FREY, P ;
SARTER, B ;
GAUTHERIE, M .
INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN ENGINEERING, 1994, 37 (16) :2735-2753
[7]   Computing strain fields from discrete displacement fields in 2D-solids [J].
Geers, MGD ;
DeBorst, R ;
Brekelmans, WAM .
INTERNATIONAL JOURNAL OF SOLIDS AND STRUCTURES, 1996, 33 (29) :4293-4307
[8]   A HOMOGENIZATION SAMPLING PROCEDURE FOR CALCULATING TRABECULAR BONE EFFECTIVE STIFFNESS AND TISSUE-LEVEL STRESS [J].
HOLLISTER, SJ ;
BRENNAN, JM ;
KIKUCHI, N .
JOURNAL OF BIOMECHANICS, 1994, 27 (04) :433-444
[9]   Survey:: Interpolation methods in medical image processing [J].
Lehmann, TM ;
Gönner, C ;
Spitzer, K .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (11) :1049-1075
[10]  
Lorensen WE, 1987, COMPUT GRAPH, DOI 10.1145/37401.37422