Software-triggered contrast-enhanced three-dimensional MR angiography of the intracranial arteries

被引:16
作者
Isoda, H
Takehara, Y
Isogai, S
Takeda, H
Tanaka, T
Takahashi, M
Nozaki, A
Sun, Y
机构
[1] Hamamatsu Univ Sch Med, Dept Radiol, Hamamatsu, Shizuoka 4313192, Japan
[2] Hamamatsu Univ Sch Med, Dept Neurosurg, Hamamatsu, Shizuoka 4313192, Japan
[3] Gen Elect Yokogawa Med Syst Ltd, Tokyo 1918503, Japan
[4] Gen Elect Med Syst, Waukesha, WI 53188 USA
关键词
D O I
10.2214/ajr.174.2.1740371
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. We investigated the effectiveness of software-triggered contrast-enhanced three-dimensional (3D) MR angiography in evaluating intracranial arteries. SUBJECTS AND METHODS. We studied 38 patients with suspected brain lesions. Imaging was performed using a 1.5-T superconducting MR system with a commercially available head coil. To monitor signal intensity changes we used software to place a tracker volume at the basilar artery or the internal carotid artery. A 20-ml bolus of gadodiamide hydrate was administered through the antecubital vein at a rate of 2-4 ml/sec, followed by a saline flush. Three-dimensional MR angiography using a spoiled gradient-echo sequence with centric K-space ordering was triggered by the arrival of the contrast bolus in the tracker volume. Imaging times ranged from 12 to 20 sec. We used MR images to assess the effectiveness of contrast-enhanced 3D MR angiography in revealing intracranial arteries with minimal venous overlap. RESULTS. The software triggered imaging on the arrival of the contrast bolus in 81.6% of examinations. In 77.6% of examinations, the resulting MR angiograms revealed intracranial arteries with minimal venous overlap. CONCLUSION. Software-triggered contrast-enhanced 3D MR angiography with centric K-space ordering is a promising technique for viewing intracranial arteries.
引用
收藏
页码:371 / 375
页数:5
相关论文
共 15 条
[1]   REDUCTION OF PARTIAL-VOLUME ARTIFACTS WITH ZERO-FILLED INTERPOLATION IN 3-DIMENSIONAL MR-ANGIOGRAPHY [J].
DU, YPP ;
PARKER, DL ;
DAVIS, WL ;
CAO, G .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (05) :733-741
[2]   Automated detection of bolus arrival and initiation of data acquisition in fast, three-dimensional, gadolinium-enhanced MR angiography [J].
Foo, TKF ;
Saranathan, M ;
Prince, MR ;
Chenevert, TL .
RADIOLOGY, 1997, 203 (01) :275-280
[3]  
Isoda H, 1998, AM J NEURORADIOL, V19, P1241
[4]   CLINICAL-EVALUATION OF PULMONARY 3D TIME-OF-FLIGHT MRA WITH BREATH-HOLDING USING CONTRAST-MEDIA [J].
ISODA, H ;
USHIMI, T ;
MASUI, T ;
MOCHIZUKI, T ;
GOTO, S ;
SUZUKI, K ;
SHIRAKAWA, T ;
OHTA, A ;
TAKAHASHI, M ;
KANEKO, M .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1995, 19 (06) :911-919
[5]   CONTRAST-ENHANCED MR-ANGIOGRAPHY FOR THE DIAGNOSIS OF INTRACRANIAL VASCULAR-DISEASE - OPTIMAL DOSE OF GADOPENTETATE DIMEGLUMINE [J].
JUNG, HW ;
CHANG, KH ;
CHOI, DS ;
HAN, MH ;
HAN, MC .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (05) :1251-1255
[6]   Arterial-phase three-dimensional contrast-enhanced MR angiography of the carotid arteries [J].
Levy, RA ;
Prince, MR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (01) :211-215
[7]   The effects of time varying intravascular signal intensity and k-space acquisition order on three-dimensional MR angiography image quality [J].
Maki, JH ;
Prince, MR ;
Londy, FJ ;
Chenevert, TL .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (04) :642-651
[8]  
Milburn JM, 1997, AM J NEURORADIOL, V18, P1081
[9]   Nephrotoxicity of high-dose gadolinium compared with iodinated contrast [J].
Prince, MR ;
Arnoldus, C ;
Frisoli, JK .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (01) :162-166
[10]   Contrast-enhanced abdominal MR angiography: Optimization of imaging delay time by automating the detection of contrast material arrival in the aorta [J].
Prince, MR ;
Chenevert, TL ;
Foo, TKF ;
Londy, FJ ;
Ward, JS ;
Maki, JH .
RADIOLOGY, 1997, 203 (01) :109-114