Development of a tubular sensor based on a polypyrrole-doped membrane for the potentiometric determination of the dodecylsulfate anion in a FIA system

被引:14
作者
Alvarez-Romero, GA
Morales-Pérez, A
Rojas-Hernández, A
Palomar-Pardavé, M
Ramírez-Silva, MT
机构
[1] Univ Autonoma Metropolitana Iztapalapa, Dept Quim, Mexico City 09340, DF, Mexico
[2] Univ Nacl Autonoma Mexico, Fac Estudios Super Cuautitlan, Cuautitlan 54750, Izcalli, Mexico
[3] Univ Autonoma Metropolitana Azcapotzalco, Dept Mat, Mexico City 02200, DF, Mexico
关键词
dodecylsulfate; ion-selective electrode; polypyrrole; SIMPLEX; FIA;
D O I
10.1002/elan.200302935
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Potentiostatic polymerization of polypyrrole doped with dodecylsulfate anion (DS-) was carried out in situ over a tubular composite (graphite-epoxy resin) support in order to develop a potentiometric DS- sensor (TISE) suitable for flow injection analysis (FIA). The sensibility of the TISE was maximized using the SIMPLEX algorithm in terms of the concentration of the pyrrole monomer, the concentration of DS-, the potential imposed and polymerization time. Response times between 2 and 4 minutes were observed. The analytical parameters obtained with the flow system were compared with those obtained in batch studies. In both, flow and batch analysis, potential vs. DS- concentration curves displayed two linear regions with different slopes. Flow analysis for DS- ion brings a total linear range of 1.58 x 10(-5) M to 3.88 x 10(-3) M with a maximum sensibility of 36.4 mV/concentration decade, meanwhile in batch studies the total linear range found was of 6.31 x 10(-6) M to 1.0 x 10(-3) M with a maximum sensibility of 54.49 mV The flow system response pH range was from 5 to 8. The reproducibility in terms of the relative error of the mean of different experiments was 1.58%. Two salient features of the system designed and built are worthy of mention: the sensor presented high selectivity to the dodecyl sulfate ion as compared to other inorganic anions including other anionic surfactants. The sensor lifetime in the FIA system by means of the sensibility changes was found to be of approximately four months.
引用
收藏
页码:1236 / 1243
页数:8
相关论文
共 32 条
[1]   FLOW-INJECTION SYSTEM FOR ONLINE POTENTIOMETRIC MONITORING OF AMMONIA IN FRESH-WATER STREAMS [J].
ALEGRET, S ;
ALONSO, J ;
BARTROLI, J ;
MARTINEZFABREGAS, E .
ANALYST, 1989, 114 (11) :1443-1447
[2]   ELECTROCHEMICAL STUDY OF THE MICELLIZATION OF HEXADECYLPYRIDINIUM BROMIDE IN BINARY METHANOL-WATER MIXTURES [J].
ALIZADEH, N ;
GHARIBI, H ;
SHAMSIPUR, M .
BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 1995, 68 (03) :730-733
[3]  
Alizadeh N, 2000, ELECTROANAL, V12, P509, DOI 10.1002/(SICI)1521-4109(200005)12:7<509::AID-ELAN509>3.0.CO
[4]  
2-U
[5]   Linear alkylbenzenesulfonate (LAS) ion-selective electrode based on electrochemically prepared polypyrrole and PVC [J].
Alizadeh, N ;
Khodaei-Tazekendi, H .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 75 (1-2) :5-10
[6]   CLAY MEMBRANE ELECTRODES SPECIFIC TO CATIONIC SURFACTANTS - APPLICATIONS [J].
BAILLARGER, C ;
MAYAFFRE, A ;
TURMINE, M ;
LETELLIER, P ;
SUQUET, H .
ELECTROCHIMICA ACTA, 1994, 39 (06) :813-816
[7]   SEPARATION OF SULFONATE AND SULFATE SURFACTANTS BY CAPILLARY ELECTROPHORESIS - EFFECT OF BUFFER CATION [J].
CHEN, SH ;
PIETRZYK, DJ .
ANALYTICAL CHEMISTRY, 1993, 65 (20) :2770-2775
[8]   CHLORIDE CHEMICAL SENSOR BASED ON AN ORGANIC CONDUCTING POLYPYRROLE POLYMER [J].
DONG, SJ ;
SUN, ZS ;
LU, ZL .
ANALYST, 1988, 113 (10) :1525-1528
[9]   TITRATIONS OF NONIONIC SURFACTANTS WITH SODIUM TETRAPHENYLBORATE USING THE ORION SURFACTANT ELECTRODE [J].
GALLEGOS, RD .
ANALYST, 1993, 118 (09) :1137-1141
[10]   Potentiometric analysis of ionic surfactants by a new type of ion-selective electrode [J].
Gerlache, M ;
Senturk, Z ;
Vire, JC ;
Kauffmann, JM .
ANALYTICA CHIMICA ACTA, 1997, 349 (1-3) :59-65