Evaluation of the SAS Legionella Test, a new immunochromatographic assay for the detection of Legionella pneumophila serogroup 1 antigen in urine

被引:15
作者
Diederen, B. M. W. [1 ]
Peeters, M. F. [1 ]
机构
[1] St Elizabeth Hosp, Lab Med Microbiol & Immunol, Tilburg, Netherlands
关键词
diagnosis; evaluation; Legionella pneumophila; SAS Legionella Test; urinary antigen test;
D O I
10.1111/j.1469-0691.2006.01587.x
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
This study evaluated a new immunochromatographic assay (SAS Legionella Test) for its ability to detect Legionella pneumophila serogroup 1 antigen in urine. Results were compared with those obtained using the Binax Now urinary antigen test. Sensitivity and specificity were estimated as 82.9% and 99.0%, respectively, for the SAS Legionella Test, and 91.4% and 100%, respectively, for the Binax Now urinary antigen test. The sensitivity of both tests increased to 97.1% (p 0.009) and 94.2% (p 0.7), respectively, if the tests were examined after 1 h.
引用
收藏
页码:86 / 88
页数:3
相关论文
共 15 条
[1]  
BERDAL BP, 1979, J CLIN MICROBIOL, V9, P575
[2]  
Breiman R F, 1998, Semin Respir Infect, V13, P84
[3]   Case of false-positive results of the urinary antigen test for Legionella pneumophila [J].
Deforges, L ;
Legrand, P ;
Tankovic, J ;
Brun-Buisson, C ;
Lang, P ;
Soussy, CJ .
CLINICAL INFECTIOUS DISEASES, 1999, 29 (04) :953-954
[4]   Diagnosis of Legionella infection in Legionnaires' disease [J].
Den Boer, JW ;
Yzerman, EPF .
EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2004, 23 (12) :871-878
[5]   Evaluation of a rapid immunochromatographic assay for the detection of Legionella antigen in urine samples [J].
Domínguez, J ;
Galí, N ;
Matas, L ;
Pedroso, P ;
Hernández, A ;
Padilla, E ;
Ausina, V .
EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 1999, 18 (12) :896-898
[6]  
Domínguez JA, 1998, J CLIN MICROBIOL, V36, P2718
[7]   Legionella and Legionnaires' disease:: 25 years of investigation [J].
Fields, BS ;
Benson, RF ;
Besser, RE .
CLINICAL MICROBIOLOGY REVIEWS, 2002, 15 (03) :506-+
[8]   Comparison of diagnostic sensitivities of three assays (Bartels enzyme immunoassay [EIA], Biotest EIA, and Binax NOW immunochromatographic test) for detection of Legionella pneumophila serogroup 1 antigen in urine [J].
Guerrero, C ;
Toldos, CM ;
Yagüe, G ;
Ramírez, C ;
Rodríguez, T ;
Segovia, M .
JOURNAL OF CLINICAL MICROBIOLOGY, 2004, 42 (01) :467-468
[9]  
Harrison Timothy, 1998, Clin Microbiol Infect, V4, P359, DOI 10.1111/j.1469-0691.1998.tb00079.x
[10]   Detection of Legionella pneumophila antigen in urine samples by the BinaxNOW immunochromatographic assay and comparison with both Binax Legionella Urinary Enzyme Immunoassay (EIA) and Biotest Legionella urinary antigen EIA [J].
Helbig, JH ;
Uldum, SA ;
Lück, PC ;
Harrison, TG .
JOURNAL OF MEDICAL MICROBIOLOGY, 2001, 50 (06) :509-516