Lithium sensor based on the laser scanning semiconductor transducer

被引:22
作者
Ermolenko, Y
Yoshinobu, T
Mourzina, Y
Furuichi, K
Levichev, S
Vlasov, Y
Schöning, MJ
Iwasaki, H
机构
[1] Forschungszentrum Julich, Inst Thin Films & Interfaces, D-52425 Julich, Germany
[2] Osaka Univ, Inst Sci & Ind Res, Osaka, Japan
[3] St Petersburg State Univ, Fac Chem, St Petersburg 198904, Russia
[4] Univ Appl Sci Aachen, Dept Julich, Julich, Germany
关键词
light-addressable potentiometric sensor; lithium sensitivity; ionophore; polymeric membrane;
D O I
10.1016/S0003-2670(02)00102-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A lithium-selective polymeric membrane has been immobilised on the surface of a semiconductor transducer. This light-address able potentiometric sensor (LAPS) with the induced lithium selectivity has been prepared with the aim at further development of a Li(+) assay in liquid media, including biological fluids. The sensor developed exhibits Nernstian response interval of 10(-5) to 10(-1) mol l(-1) with an ionic sensitivity of (58 +/- 1)mV/pLi. The detection limit was found to be (3 +/- 1) x 10(-6) mol l(-1) Li(+). The sensor has high selectivity for lithium over sodium and potassium ions with selectivity coefficients of K(Li/Na)(POT) = (7 +/- 2) x 10(-3) and K(Li/K)(POT) = (5 +/- 1) X 10(-3) respectively, and a response time of less than 30 s. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 44 条
[1]  
AKADOV JY, 1972, DIELECTRIC PROPERTIE, P64
[2]   NEUTRAL CARRIER BASED ION-SELECTIVE ELECTRODE FOR THE DETERMINATION OF TOTAL CALCIUM IN BLOOD-SERUM [J].
ANKER, P ;
WIELAND, E ;
AMMANN, D ;
DOHNER, RE ;
ASPER, R ;
SIMON, W .
ANALYTICAL CHEMISTRY, 1981, 53 (13) :1970-1974
[3]  
ATKINS PW, 1978, PHYSICAL CHEM, P1018
[4]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[5]   SPARINGLY SELECTIVE ION-SELECTIVE ELECTRODE ARRAYS FOR MULTICOMPONENT ANALYSIS [J].
BEEBE, K ;
UERZ, D ;
SANDIFER, J ;
KOWALSKI, B .
ANALYTICAL CHEMISTRY, 1988, 60 (01) :66-71
[6]   STUDIES ON THE PHASE BOUNDARIES AND THE SIGNIFICANCE OF IONIC SITES OF LIQUID MEMBRANE ION-SELECTIVE ELECTRODES [J].
BUHLMANN, P ;
YAJIMA, S ;
TOHDA, K ;
UMEZAWA, K ;
NISHIZAWA, S ;
UMEZAWA, Y .
ELECTROANALYSIS, 1995, 7 (09) :811-816
[7]   EMF RESPONSE OF NEUTRAL-CARRIER BASED ION-SENSITIVE FIELD-EFFECT TRANSISTORS WITH MEMBRANES FREE OF IONIC SITES [J].
BUHLMANN, P ;
YAJIMA, S ;
TOHDA, K ;
UMEZAWA, Y .
ELECTROCHIMICA ACTA, 1995, 40 (18) :3021-3027
[8]  
CAMMAN K, 1996, ARBEITEN IONENSELEKT, P296
[9]  
DOMANS LB, 1961, J CHEM ENG DATA, V6, P56
[10]  
ERMOLENKO Y, 2001, P INT C AN SCI TOK J