Tissue engineering of autologous aorta using a new biodegradable polymer

被引:210
作者
Shum-Tim, D
Stock, U
Hrkach, J
Shinoka, T
Lien, J
Moses, MA
Stamp, A
Taylor, G
Moran, AM
Landis, W
Langer, R
Vacanti, JP
Mayer, JE
机构
[1] Harvard Univ, Sch Med, Childrens Hosp, Dept Cardiovasc Surg, Boston, MA 02115 USA
[2] Harvard Univ, Sch Med, Childrens Hosp, Dept Surg Radiol, Boston, MA 02115 USA
[3] Harvard Univ, Sch Med, Childrens Hosp, Dept Cardiol, Boston, MA 02115 USA
[4] Harvard Univ, Sch Med, Childrens Hosp, Dept Orthoped Surg, Boston, MA 02115 USA
[5] MIT, Dept Chem Engn, Cambridge, MA 02139 USA
关键词
D O I
10.1016/S0003-4975(99)01055-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Ovine pulmonary valve leaflets and pulmonary arteries have been tissue-engineered (TE) from autologous cells and biodegradable polyglycolic acid (PGA)-polyglactin copolymers. Use of this cell-polymer construct in the systemic circulation resulted in aneurysm formation. This study evaluates a TE vascular graft in the systemic circulation which is based on a new copolymer of PGA and polyhydroxyalkanoate (PHA). Methods. Ovine carotid arteries were harvested, expanded in vitro, and seeded onto 7-mm diameter PHA-PGA tubular scaffolds. The autologous cell-polymer vascular constructs were used to replace 3-4 cm abdominal aortic segments in lambs (group TE, n = 7). In a control group (n = 4), aortic segments were replaced with acellular polymer tubes. Vascular patency was evaluated with echography. All control animals were sacrificed when the grafts became occluded. Animals in TE group were sacrificed at 10 days (n = 1), 3 (n = 3), and 5 months (n = 3). Explanted TE conduits were evaluated for collagen content, deoxyribonucleic acid (DNA) content, structural and ultrastructural examination, mechanical strength, and matrix metalloproteinase (MMP) activity. Results. The 4 control conduits became occluded at 1, 2, 55, and 101 days. All TE grafts remained patent, and no aneurysms developed by the time of sacrifice. There was one mild stenosis at the anastomotic site after 5 months postoperatively. The percent collagen and DNA contents approached the native aorta over time (% collagen = 25.7% +/- 3.4 [3 months] vs 99.6% +/- 11.7 [5 months], p < 0.05; and % DNA = 30.8% +/- 6.0 [3 months] vs 150.5% +/- 16.9 [5 months], p < 0.05). Histology demonstrated elastic fibers in the medial layer and endothelial specific von Willebrand factor on the luminal surface. The mechanical strain-stress curve of the TE aorta approached that of the native vessel. A 66 kDa MMP-2 was found in the TE and native aorta but not in control group. Conclusions. Autologous aortic grafts with biological characteristics resembling the native aorta can be created using TE approach. This may allow the development of "live" vascular grafts. (C) 1999 by The Society of Thoracic Surgeons.
引用
收藏
页码:2298 / 2304
页数:7
相关论文
共 20 条
[1]  
Breuer CK, 1996, BIOTECHNOL BIOENG, V50, P562, DOI 10.1002/(SICI)1097-0290(19960605)50:5<562::AID-BIT11>3.0.CO
[2]  
2-L
[3]   A DECADE OF EXPERIENCE WITH THE GLUTARALDEHYDE-TANNED HUMAN UMBILICAL-CORD VEIN GRAFT FOR REVASCULARIZATION OF THE LOWER-LIMB [J].
DARDIK, H ;
MILLER, N ;
DARDIK, A ;
IBRAHIM, IM ;
SUSSMAN, B ;
BERRY, SM ;
WOLODIGER, F ;
KAHN, M ;
DARDIK, I .
JOURNAL OF VASCULAR SURGERY, 1988, 7 (02) :336-346
[4]   SUCCESSFUL ARTERIAL SUBSTITUTION WITH MODIFIED HUMAN UMBILICAL VEIN [J].
DARDIK, H ;
DARDIK, II .
ANNALS OF SURGERY, 1976, 183 (03) :252-258
[5]   Biointeractive polymers and tissue engineered blood vessels [J].
Greisler, HP ;
Gosselin, C ;
Ren, DW ;
Kang, SS ;
Kim, DU .
BIOMATERIALS, 1996, 17 (03) :329-336
[6]  
GREISLER HP, 1982, ARCH SURG-CHICAGO, V117, P1425
[7]   POLYPROPYLENE SMALL-DIAMETER VASCULAR GRAFTS [J].
GREISLER, HP ;
TATTERSALL, CW ;
HENDERSON, SC ;
CABUSAO, EA ;
GARFIELD, JD ;
KIM, DU .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1992, 26 (10) :1383-1394
[8]  
GRIESLER HP, 1987, ARCH SURG-CHICAGO, V122, P715
[9]  
Jones L, 1997, Cardiovasc Surg, V5, P486, DOI 10.1016/S0967-2109(97)00056-2
[10]   THE INFLUENCE OF SHEAR-STRESS ON CULTURED VASCULAR ENDOTHELIAL-CELLS - THE STRESS RESPONSE OF AN ANCHORAGE-DEPENDENT MAMMALIAN-CELL [J].
LEVESQUE, MJ ;
SPRAGUE, EA ;
SCHWARTZ, CJ ;
NEREM, RM .
BIOTECHNOLOGY PROGRESS, 1989, 5 (01) :1-8