Optical glucose sensing in biological fluids:: an overview

被引:313
作者
McNichols, RJ [1 ]
Coté, GL [1 ]
机构
[1] Texas A&M Univ, Biomed Engn Program, College Stn, TX 77843 USA
关键词
glucose sensing; polarimetry raman spectroscopy; infrared absorption; fluorescence;
D O I
10.1117/1.429962
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Recent technological advancements in the photonics industry have led to a resurgence of interest in optical glucose sensing and to realistic progress toward the development of an optical glucose sensor. Such a sensor has the potential to significantly improve the quality of life for the estimated 16 million diabetics in this country by making routine glucose measurements more convenient. Currently over 100 small companies and universities are working to develop noninvasive or minimally invasive glucose sensing technologies, and optical methods play a large role in these efforts. This article reviews many of the recent advances in optical glucose sensing including optical absorption spectroscopy, polarimetry, Raman spectroscopy, and fluorescent glucose sensing. In addition a review of calibration and data processing methods useful for optical techniques is presented. (C) 2000 Society of Photo-Optical Instrumentation Engineers. [S1083-3668(00)01401-5].
引用
收藏
页码:5 / 16
页数:12
相关论文
共 101 条
[1]   FIBER-OPTIC SENSOR FOR THE DETERMINATION OF GLUCOSE USING MICELLAR ENHANCED CHEMI-LUMINESCENCE OF THE PEROXYOXALATE REACTION [J].
ABDELLATIF, MS ;
GUILBAULT, GG .
ANALYTICAL CHEMISTRY, 1988, 60 (24) :2671-2674
[2]  
AMATO I, 1992, SCIENCE, V258, P892
[3]  
[Anonymous], SYSTEMS INDIRECT OBS
[4]  
[Anonymous], 1989, MULTIVARIATE CALIBRA
[5]   DETERMINATION OF PHYSIOLOGICAL LEVELS OF GLUCOSE IN AN AQUEOUS MATRIX WITH DIGITALLY FILTERED FOURIER-TRANSFORM NEAR-INFRARED SPECTRA [J].
ARNOLD, MA ;
SMALL, GW .
ANALYTICAL CHEMISTRY, 1990, 62 (14) :1457-1464
[6]   Competitive-binding assay method based on fluorescence quenching of ligands held in close proximity by a multivalent receptor [J].
Ballerstadt, R ;
Schultz, JS .
ANALYTICA CHIMICA ACTA, 1997, 345 (1-3) :203-212
[7]   Genetic algorithm-based method for selecting wavelengths and model size for use with partial least-squares regression: Application to near-infrared spectroscopy [J].
Bangalore, AS ;
Shaffer, RE ;
Small, GW ;
Arnold, MA .
ANALYTICAL CHEMISTRY, 1996, 68 (23) :4200-4212
[8]   An enhanced algorithm for linear multivariate calibration [J].
Berger, AJ ;
Koo, TW ;
Itzkan, I ;
Feld, MS .
ANALYTICAL CHEMISTRY, 1998, 70 (03) :623-627
[9]   Feasibility of measuring blood glucose concentration by near-infrared Raman spectroscopy [J].
Berger, AJ ;
Itzkan, I ;
Feld, MS .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 1997, 53 (02) :287-292
[10]   MULTIVARIATE DETERMINATION OF GLUCOSE IN WHOLE-BLOOD USING PARTIAL LEAST-SQUARES AND ARTIFICIAL NEURAL NETWORKS BASED ON MIDINFRARED SPECTROSCOPY [J].
BHANDARE, P ;
MENDELSON, Y ;
PEURA, RA ;
JANATSCH, G ;
KRUSEJARRES, JD ;
MARBACH, R ;
HEISE, HM .
APPLIED SPECTROSCOPY, 1993, 47 (08) :1214-1221