This paper investigates the use of identified nonlinear multivariable autonomous models in the classification of breathing patterns of a patient with sleep apnea. Details about the identification procedure are provided and the results reported for the case study at hand suggest that identified models could be useful in computer-based monitoring. (C) 2003 Elsevier Ltd. All rights reserved.
引用
收藏
页码:241 / 257
页数:17
相关论文
共 19 条
[1]   Nonlinear multivariable modeling and analysis of sleep apnea time series [J].
Aguirre, LA ;
Barros, VC ;
Souza, AVP .
COMPUTERS IN BIOLOGY AND MEDICINE, 1999, 29 (03) :207-228
[2]   IMPROVED STRUCTURE SELECTION FOR NONLINEAR MODELS BASED ON TERM CLUSTERING [J].
AGUIRRE, LA ;
BILLINGS, SA .
INTERNATIONAL JOURNAL OF CONTROL, 1995, 62 (03) :569-587
[3]   NEW LOOK AT STATISTICAL-MODEL IDENTIFICATION [J].
AKAIKE, H .
IEEE TRANSACTIONS ON AUTOMATIC CONTROL, 1974, AC19 (06) :716-723
[4]  
[Anonymous], 2018, TIME SERIES PREDICTI
[5]   IDENTIFICATION OF MIMO NON-LINEAR SYSTEMS USING A FORWARD-REGRESSION ORTHOGONAL ESTIMATOR [J].
BILLINGS, SA ;
CHEN, S ;
KORENBERG, MJ .
INTERNATIONAL JOURNAL OF CONTROL, 1989, 49 (06) :2157-2189
[6]   Toward prediction of physiological state signals in sleep apnea [J].
Bock, J ;
Gough, DA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1998, 45 (11) :1332-1341
[7]   Deterministic structure in multichannel physiological data [J].
Cao, LY ;
Mees, A .
INTERNATIONAL JOURNAL OF BIFURCATION AND CHAOS, 2000, 10 (12) :2767-2780
[8]   ORTHOGONAL LEAST-SQUARES METHODS AND THEIR APPLICATION TO NON-LINEAR SYSTEM-IDENTIFICATION [J].
CHEN, S ;
BILLINGS, SA ;
LUO, W .
INTERNATIONAL JOURNAL OF CONTROL, 1989, 50 (05) :1873-1896
[9]   Analysis of heart rate and blood pressure variability during nasal continuous positive airway pressure therapy in patients with obstructive sleep apnea [J].
Glos, M ;
Romberg, D ;
Fietze, I ;
Röttig, J ;
Knobe, M ;
Witt, C .
COMPUTERS IN CARDIOLOGY 1999, VOL 26, 1999, 26 :603-605
[10]   Investigation of determinism in heart rate variability [J].
Gomes, MED ;
Souza, AVP ;
Guimaraes, HN ;
Aguirre, LA .
CHAOS, 2000, 10 (02) :398-410