Homogeneous stopped-flow fluoroimmunoassay using europium as label

被引:8
作者
Aguilar-Caballos, MP
Härmä, H
Tuomola, M
Lövgren, T
Gómez-Hens, A
机构
[1] Univ Cordoba, Fac Sci, Div Analyt Chem, Cordoba 14071, Spain
[2] Univ Turku, Dept Biotechnol, Turku, Finland
关键词
homogeneous fluoroimmunoassay; skatole; europium tracer; stopped-flow; food analysis;
D O I
10.1016/S0003-2670(02)00253-2
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学]; 081704 [应用化学];
摘要
A competitive homogeneous fluoroimmunoassay (FIA) based on the use of europium(III) as label together with kinetic methodology, is described for the first time. This approach has been applied to the determination of skatole, a compound causing boar-taint, in pig back fat samples. The analytical signal was obtained by measuring the initial rate of the dissociation reaction of europium(III) from the tracer through the formation of an intense luminescent chelate. This initial rate is higher for the free tracer than for that corresponding to the tracer bound to the antibody, and it is directly related to the analyte concentration. Each kinetic measurement was obtained in less than 1 s by using stopped-flow (SF) mixing technique. Benzoyltrifluoroacetone, tri-n-octylphosphine and Triton X-100 were used to obtain an adequate luminescent signal. The dynamic range of the calibration graph of the method is 30-300 ng ml(-1) and the calculated detection limit is 11 ng ml(-1). The precision, obtained for two skatole concentrations, 50 and 150 ng ml(-1), and expressed as relative standard deviation (n = 11), was lower than 6.5%. The method was applied to the analysis of pig back fat samples with recoveries ranging from 92 to 108%. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:271 / 277
页数:7
相关论文
共 21 条
[1]
Pesticide determination by stopped-flow fluoroimmunoassay using Cresyl Violet as label [J].
Aguilar-Caballos, MP ;
Gómez-Hens, A ;
Pérez-Bendito, D .
ANALYTICA CHIMICA ACTA, 1999, 381 (2-3) :147-154
[2]
DETERMINATION OF AFLATOXIN B-1 IN AGRICULTURAL COMMODITIES BY TIME-RESOLVED FLUOROIMMUNOASSAY AND IMMUNOENZYMOMETRIC ASSAY [J].
BACIGALUPO, MA ;
IUS, A ;
MERONI, G ;
DOVIS, M ;
PETRUZZELLI, E .
ANALYST, 1994, 119 (12) :2813-2815
[3]
BERG H, MEASUREMENT PREVENTI, P55
[4]
USE OF STOPPED-FLOW FLUORESCENCE POLARIZATION IMMUNOASSAY IN DRUG DETERMINATIONS [J].
GAIKWAD, A ;
GOMEZHENS, A ;
PEREZBENDITO, D .
ANALYTICA CHIMICA ACTA, 1993, 280 (01) :129-135
[5]
GIBIS M, 1993, DEUT LEBENSM-RUNDSCH, V89, P313
[6]
RAPID HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR SIMULTANEOUS DETERMINATION OF ANDROSTENONE, SKATOLE AND INDOLE IN BACK FAT FROM PIGS [J].
HANSENMOLLER, J .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1994, 661 (02) :219-230
[7]
EUROPIUM AS A LABEL IN TIME-RESOLVED IMMUNOFLUOROMETRIC ASSAYS [J].
HEMMILA, I ;
DAKUBU, S ;
MUKKALA, VM ;
SIITARI, H ;
LOVGREN, T .
ANALYTICAL BIOCHEMISTRY, 1984, 137 (02) :335-343
[8]
DEVELOPMENT OF A TIME-RESOLVED FLUOROIMMUNOASSAY OF BENZO(A)PYRENE IN WATER [J].
IUS, A ;
BACIGALUPO, MA ;
RODA, A ;
VACCARI, C .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 343 (01) :55-56
[9]
JANSENMOLLER J, 1992, J CHROMATOGR, V624, P479
[10]
LIMIT OF DETECTION [J].
LONG, GL ;
WINEFORDNER, JD .
ANALYTICAL CHEMISTRY, 1983, 55 (07) :A712-+