Second-generation three-dimensional reconstruction for rotational three-dimensional angiography

被引:43
作者
Bidaut, LM
Laurent, C
Piotin, M
Gailloud, P
Muster, M
Fasel, JHD
Rüfenacht, DA
Terrier, F
机构
[1] Univ Hosp Geneva, Lab Funct & Multidimens Imaging, Div Med Informat, CH-1211 Geneva 14, Switzerland
[2] Univ Hosp Geneva, Neuroradiol Unit, Div Radiodiagnost & Intervent Radiol, CH-1211 Geneva 14, Switzerland
[3] Univ Hosp Geneva, Dept Morphol, CH-1211 Geneva 14, Switzerland
[4] Univ Hosp Geneva, Dept Radiol, CH-1211 Geneva 14, Switzerland
关键词
digital subtraction angiography; technology; interventional procedures;
D O I
10.1016/S1076-6332(98)80244-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. The purpose of this study was to assess the feasibility and accuracy of three-dimensional (3D) reconstruction techniques for digital subtraction angiography (DSA) in planning and evaluation of minimally invasive image-controlled therapy. Materials and Methods, Using a standard, commercially available system, the authors acquired DSA images and corrected them for inherent distortions. They designed and implemented parallel and multiresolution versions of cone-beam reconstruction techniques to reconstruct high-resolution targeted volumes in a short period of time. Testing was performed on anatomically correct, calibrated in vitro models of a cerebral aneurysm. These models were used with a pulsatile circulation circuit to allow for blood flow simulation during DSA, computed tomographic (CT) angiography, and magnetic resonance (MR) angiography image acquisitions. Results. The multiresolution DSA-based reconstruction protocol and its implementation allowed the authors to achieve reconstruction times and levels of accuracy for the volume measurement of the aneurysmal cavities that were considered compatible with actual clinical practice. Comparison with data obtained from other imaging modalities shows that, besides vascular tree depiction, the DSB-based true 3D technique provides volume estimates at least as good as those obtained from CT and MR angiography. Conclusion. The authors demonstrated the feasibility and potential of true 3D reconstruction for angiographic imaging with DSA. On the basis of the model testing, this work addresses both the timing and quantification equi-red to support minimally invasive image-controlled therapy.
引用
收藏
页码:836 / 849
页数:14
相关论文
共 17 条
  • [1] Three- to five-dimensional biomedical multisensor imaging for the assessment of neurological (dys) function
    Bidaut, LM
    Pascual-Marqui, R
    Delavelle, J
    Naimi, A
    Seeck, M
    Michel, C
    Slosman, D
    Ratib, O
    Ruefenacht, D
    Landis, T
    deTribolet, N
    Scherrer, JR
    Terrier, F
    [J]. JOURNAL OF DIGITAL IMAGING, 1996, 9 (04) : 185 - 198
  • [2] FLEKMAP LA, 1984, J OPT SOC AM, V1, P612
  • [3] Gailloud P, 1997, SURG RADIOL ANAT, V19, P119
  • [4] GARNERO L, 1993, 9301 U LYON
  • [5] Geist A, 1994, PVM PARALLEL VIRTUAL
  • [6] GILBERT P, 1972, J THEOR BIOL, V36, P105, DOI 10.1016/0022-5193(72)90180-4
  • [7] Hounsfield G. N., 1972, Patent Specification, Patent No. 1283915
  • [8] 3D x-ray angiography: Study of factors affecting projection data consistency
    Hsiung, HH
    Sen, A
    Schueler, BA
    Hu, XP
    Latchaw, RE
    [J]. PHYSICS OF MEDICAL IMAGING - MEDICAL IMAGING 1997, 1997, 3032 : 226 - 237
  • [9] Koppe R, 1997, INT CONGR SER, V1134, P145
  • [10] KOPPE R, 1995, COMPUTER ASSISTED RADIOLOGY, P101