Coronary magnetic resonance angiography for assessment of the stent lumen: A phantom study

被引:29
作者
Maintz, D
Botnar, RM
Fischbach, R
Heindel, W
Manning, WJ
Stuber, M
机构
[1] Univ Munster, Dept Clin Radiol, D-48129 Munster, Germany
[2] Beth Israel Deaconess Med Ctr, Cardiac MR Ctr, Boston, MA 02215 USA
[3] Harvard Univ, Sch Med, Boston, MA 02115 USA
[4] Philips Med Syst, Best, Netherlands
关键词
stents and protheses; magnetic resonance angiography; coronary magnetic resonance angiography; artifacts;
D O I
10.1081/JCMR-120013303
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: To evaluate the feasibility of visualizing the stent lumen using coronary magnetic resonance angiography in vitro. Material and methods: Nineteen different coronary stents were implanted in plastic tubes with an inner diameter of 3 mm. The tubes were positioned in a plastic container filled with gel and included in a closed flow circuit (constant flow 18 cm/sec). The magnetic resonance images were obtained with a dual inversion fast spin-echo sequence. For intraluminal stent imaging, subtraction images were calculated from scans with and without flow. Subsequently, intraluminal signal properties were objectively assessed and compared. Results: As a function of the stent type, various degrees of in-stent signal attenuation were observed. Tantalum stents demonstrated minimal intraluminal signal attenuation. For nitinol stents, the stent lumen could be identified, but the intraluminal signal was markedly reduced. Steel stents resulted in the most pronounced intraluminal signal voids. Conclusions: With the present technique, radiofrequency penetration into the stents is strongly influenced by the stent material. These findings may have important implications for future stent design and stent imaging strategies.
引用
收藏
页码:359 / 367
页数:9
相关论文
共 25 条
[1]   Tissue engineered stents created from chondrocytes [J].
Amiel, GE ;
Yoo, JJ ;
Kim, BS ;
Atala, A .
JOURNAL OF UROLOGY, 2001, 165 (06) :2091-2095
[2]   MR imaging of vascular stents: effects of susceptibility, flow, and radiofrequency eddy currents [J].
Bartels, LW ;
Smits, HFM ;
Bakker, CJG ;
Viergever, MA .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2001, 12 (03) :365-371
[3]   Development of a new biodegradable intravascular polymer stent with simultaneous incorporation of bioactive substances [J].
Blindt, R ;
Hoffmeister, KM ;
Bienert, H ;
Pfannschmitt, O ;
Bartsch, G ;
Thissen, H ;
Klee, D ;
Vom Dahl, J .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1999, 22 (12) :843-853
[4]  
Botnar R M, 2001, Cardiol Rev, V9, P77, DOI 10.1097/00045415-200103000-00006
[5]   INTRAARTERIAL BIOCOMPATIBILITY OF POLYETHYLENE TEREPHTHALATE SELF-EXPANDABLE STENTS IMPLANTED IN PORCINE PERIPHERAL ARTERIES [J].
DESCHEERDER, IK ;
WILCZEK, KV ;
VERBEKEN, EV ;
BARIOS, L ;
PIESSENS, J ;
DEGEEST, H .
ACADEMIC RADIOLOGY, 1995, 2 (02) :154-158
[6]   Assessment of coronary artery patency after stent placement using magnetic resonance angiography [J].
Duerinckx, AJ ;
Atkinson, D ;
Hurwitz, R .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (04) :896-902
[7]   LONG-TERM ANGIOGRAPHIC AND CLINICAL OUTCOME AFTER IMPLANTATION OF BALLOON-EXPANDABLE STENTS IN AORTOCORONARY SAPHENOUS-VEIN GRAFTS [J].
FENTON, SH ;
FISCHMAN, DL ;
SAVAGE, MP ;
SCHATZ, RA ;
LEON, MB ;
BAIM, DS ;
KING, SB ;
HEUSER, RR ;
CURRY, RC ;
RAKE, RC ;
GOLDBERG, S .
AMERICAN JOURNAL OF CARDIOLOGY, 1994, 74 (12) :1187-1191
[8]   Coronary arterial stents: Safety and artifacts during MR imaging [J].
Hug, J ;
Nagel, E ;
Bornstedt, A ;
Schnackenburg, B ;
Oswald, H ;
Fleck, E .
RADIOLOGY, 2000, 216 (03) :781-787
[9]   Restenosis after coronary placement of various stent types [J].
Kastrati, A ;
Mehilli, J ;
Dirschinger, J ;
Pache, J ;
Ulm, K ;
Schühlen, H ;
Seyfarth, M ;
Schmitt, C ;
Blasini, R ;
Neumann, FJ ;
Schömig, A .
AMERICAN JOURNAL OF CARDIOLOGY, 2001, 87 (01) :34-39
[10]   Predictive factors of restenosis after coronary stent placement [J].
Kastrati, A ;
Schomig, A ;
Elezi, S ;
Schuhlen, H ;
Dirschinger, J ;
Hadamitzky, M ;
Wehinger, A ;
Hausleiter, J ;
Walter, H ;
Neumann, FJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (06) :1428-1436