Testing different biphasic waveforms and capacitances: Effect on atrial defibrillation threshold and pain perception

被引:55
作者
Tomassoni, G [1 ]
Newby, KH [1 ]
Kearney, MM [1 ]
Brandon, MJ [1 ]
Barold, H [1 ]
Natale, A [1 ]
机构
[1] DUKE UNIV,VET AFFAIRS MED CTR,ELECTROPHYSIOL LAB,DURHAM,NC 27705
关键词
D O I
10.1016/0735-1097(96)00220-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. The goal of this study was to compare the effect of different tilts and capacitances for biphasic shocks on atrial defibrillation efficacy and pain threshold. Background. Although biphasic shocks have been shown to be superior to monophasic shocks, the effect of tilt and capacitance on atrial defibrillation success and pain perception has not been studied in patients. Methods. Atrial defibrillation threshold (DFT) testing was performed using a right atrial appendage/coronary sinus lead configuration in 38 patients with a history of paroxysmal atrial fibrillation undergoing an invasive electrophysiologic study. Biphasic waveforms with 40%, 50%, 65%, 80%, 30%/50% and 40%/50% were tested randomly in 22 patients (Group 1). In 16 patients (Group 2), a 65% tilt waveform with 50- and 120-mu F capacitance was tested. Before sedation, pain sensation was graded by 15 patients in Group 1 after delivery of a 0.5-J shock and by 10 patients in Group 2 after two 1.5-J shocks with 50 and 120-mu F capacitance were delivered. Results. The DFT energy for the 50% tilt waveform was significantly lower than the 65%, 80% and 30%/50% tilt waveforms. The 40%/50% tilt waveform provided slightly lower energy requirements than the 50% tilt waveform. Nine patients (60%) described the 0.5-J shock as very painful, and four (26.6%) complained of slight pain. The 50-mu F capacitor lowered energy requirements compared with the 120-mu F capacitor. Six patients (60%) perceived the 1.5-J 50-mu F capacitor shock as more painful, whereas three (30%) perceived both shocks as equally painful. Conclusions. Biphasic waveforms with 50% tilt in both phases and a smaller tilt in the positive phase than that in the negative phase (40%/50%) provided a decrease in energy requirements at atrial DPT. In addition, stored energy was reduced by biphasic shocks with 50-mu F capacitance compared with 120-mu F capacitance. Despite the reduction in energy requirements, shocks <1 J continued to be perceived as painful in the majority of patients.
引用
收藏
页码:695 / 699
页数:5
相关论文
共 22 条
[1]   A PROSPECTIVE RANDOMIZED EVALUATION OF BIPHASIC VERSUS MONOPHASIC WAVEFORM PULSES ON DEFIBRILLATION EFFICACY IN HUMANS [J].
BARDY, GH ;
IVEY, TD ;
ALLEN, MD ;
JOHNSON, G ;
MEHRA, R ;
GREENE, HL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (03) :728-733
[2]  
BOURLAND JD, 1978, MED INSTRUM, V12, P38
[3]   INTERNAL CARDIOVERSION OF ATRIAL-FIBRILLATION IN SHEEP [J].
COOPER, RAS ;
ALFERNESS, CA ;
SMITH, WM ;
IDEKER, RE .
CIRCULATION, 1993, 87 (05) :1673-1686
[4]   IMPROVED DEFIBRILLATION THRESHOLDS WITH LARGE CONTOURED EPICARDIAL ELECTRODES AND BIPHASIC WAVE-FORMS [J].
DIXON, EG ;
TANG, ASL ;
WOLF, PD ;
MEADOR, JT ;
FINE, MJ ;
CALFEE, RV ;
IDEKER, RE .
CIRCULATION, 1987, 76 (05) :1176-1184
[5]   STRENGTH DURATION AND PROBABILITY OF SUCCESS CURVES FOR DEFIBRILLATION WITH BIPHASIC WAVE-FORMS [J].
FEESER, SA ;
TANG, ASL ;
KAVANAGH, KM ;
ROLLINS, DL ;
SMITH, WM ;
WOLF, PD ;
IDEKER, RE .
CIRCULATION, 1990, 82 (06) :2128-2141
[6]   SUPERIORITY OF BIPHASIC SHOCKS IN THE DEFIBRILLATION OF DOGS BY EPICARDIAL PATCHES AND CATHETER ELECTRODES [J].
FLAKER, GC ;
SCHUDER, JC ;
MCDANIEL, WC ;
STOECKLE, H ;
DBEIS, M .
AMERICAN HEART JOURNAL, 1989, 118 (02) :288-291
[7]   THE FUNDAMENTAL LAW OF ELECTROSTIMULATION AND ITS APPLICATION TO DEFIBRILLATION [J].
IRNICH, W .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1990, 13 (11) :1433-1447
[8]   IMPACT OF PULSE CHARACTERISTICS ON ATRIAL DEFIBRILLATION ENERGY-REQUIREMENTS [J].
KEANE, D .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (05) :1048-1057
[9]   COMPARISON OF BIPHASIC AND MONOPHASIC WAVE-FORMS IN EPICARDIAL ATRIAL DEFIBRILLATION [J].
KEANE, D ;
BOYD, E ;
ANDERSON, D ;
ROBLES, A ;
DEVERALL, P ;
MORRIS, R ;
JACKSON, G ;
SOWTON, E .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 24 (01) :171-176
[10]   A MINIMAL MODEL OF THE SINGLE CAPACITOR BIPHASIC DEFIBRILLATION WAVE-FORM [J].
KROLL, MW .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (11) :1782-1792