Monolithic silica liquid chromatography columns for the determination of cyclooxygenase II inhibitors in human plasma

被引:35
作者
Vallano, PT [1 ]
Mazenko, RS [1 ]
Woolf, EJ [1 ]
Matuszewski, BK [1 ]
机构
[1] Merck Res Labs, Dept Drug Metab, West Point, PA 19486 USA
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2002年 / 779卷 / 02期
关键词
monolithic silica columns; cyclooxygenase II inhibitors;
D O I
10.1016/S1570-0232(02)00380-X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Methods employing monolithic HPLC columns for the determination of the cyclooxygenase H inhibitors rofecoxib (I) and 3-isopropoxy-4-(4-methanesulfonylphenyl)-5,5'-dimethyl-5H-furan-2-one (DFP, III) in human plasma are described. Each analyte, together with an internal standard was extracted from the plasma matrix using solid-phase extraction in the 96-well format. The analytes were chromatographed on a Chromolidi Speed Rod monolithic HPLC column (4.6 x 50 mm). Analyte detection for rofecoxib was via fluorescence following post-column photochemical derivatization. Detection for HI was based on the native fluorescence of the compound. The precision, accuracy, and linearity of the methods were found to be comparable to those obtained using methods employing conventional packed HPLC columns. Use of the monolithic column permitted mobile phase flow-rates of up to 6.5 ml/min to be employed in the assays. The use of elevated flow-rates enabled the per sample analysis time to be reduced by up to a factor of 5 compared with assays based on packed HPLC columns. The results of experiments aimed at evaluating the ruggedness and reproducibility of monolithic columns employed in bioanalytical methods are presented. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:249 / 257
页数:9
相关论文
共 10 条
[1]  
Cabrera K, 2000, HRC-J HIGH RES CHROM, V23, P93
[2]  
Dear G, 2001, RAPID COMMUN MASS SP, V15, P152, DOI 10.1002/1097-0231(20010130)15:2<152::AID-RCM206>3.3.CO
[3]  
2-R
[4]  
Giddings J.C., 1991, Unified separation science
[5]   Efficacy and tolerability of the specific cyclooxygenase-2 inhibitor DFP compared with naproxen sodium in patients with postoperative dental pain [J].
Gottesdiener, K ;
Mehlisch, DR ;
Huntington, M ;
Yuan, WY ;
Brown, P ;
Gertz, B ;
Mills, S .
CLINICAL THERAPEUTICS, 1999, 21 (08) :1301-1312
[6]   Sar in the alkoxy lactone series:: The discovery of DFP, a potent and orally active COX-2 inhibitor [J].
Leblanc, Y ;
Roy, P ;
Boyce, S ;
Brideau, C ;
Chan, CC ;
Charleson, S ;
Gordon, R ;
Grimm, E ;
Guay, J ;
Léger, S ;
Li, CS ;
Riendeau, D ;
Visco, D ;
Wang, Z ;
Webb, J ;
Xu, LJ ;
Prasit, P .
BIOORGANIC & MEDICINAL CHEMISTRY LETTERS, 1999, 9 (15) :2207-2212
[7]   Improved procedure for the the determination of rofecoxib in human plasma involving 96-well solid-phase extraction and fluorescence detection [J].
Matthews, CZ ;
Woolf, EJ ;
Matuszewski, BK .
JOURNAL OF CHROMATOGRAPHY A, 2002, 949 (1-2) :83-89
[8]   Effect of skeleton size on the performance of octadecylsilylated continuous porous silica columns in reversed-phase liquid chromatography [J].
Minakuchi, H ;
Nakanishi, K ;
Soga, N ;
Ishizuka, N ;
Tanaka, N .
JOURNAL OF CHROMATOGRAPHY A, 1997, 762 (1-2) :135-146
[9]   PHASE-SEPARATION IN SILICA SOL-GEL SYSTEM CONTAINING POLYACRYLIC-ACID .1. GEL FORMATION BEHAVIOR AND EFFECT OF SOLVENT COMPOSITION [J].
NAKANISHI, K ;
SOGA, N .
JOURNAL OF NON-CRYSTALLINE SOLIDS, 1992, 139 (01) :1-13
[10]   Direct analysis of pharmaceutical compounds in human plasma with chromatographic resolution using an alkyl-bonded silica rod column [J].
Plumb, R ;
Dear, G ;
Mallet, D ;
Ayrton, J .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (12) :986-993