Fundamental characteristics of superconducting fault current limiter using LC resonance circuit

被引:27
作者
Arai, H. [1 ]
Inaba, M.
Ishigohka, T.
Tanaka, H.
Arai, K.
Furuse, M.
Umeda, M.
机构
[1] Seikei Univ, Tokyo 1808633, Japan
[2] Hitachi Ltd, Ibaraki 3191292, Japan
[3] Natl Inst Adv Ind Sci & Technol, Tsukuba, Ibaraki 3058568, Japan
关键词
HTS coil; LC resonance circuit; superconducting fault current limiter;
D O I
10.1109/TASC.2006.870521
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new type of fault current limiter (FCL) utilizing series LC resonance circuit composed of a superconducting coil and a capacitor is proposed. The superconducting coil is wound by Bi-2223/Ag HTS tape conductor. The new FCL can suppress the rapid increase of a fault current by its energy storing capacity. Both theoretical analysis and experiments are carried out. The experimental result shows the current limiting ability of this FCL. The obtained experimental result agrees well with the theoretical one.
引用
收藏
页码:642 / 645
页数:4
相关论文
共 1 条
[1]  
ARAI H, 2003, P 71 M CRYOG SUP CRY, P26