Uniform vascular contrast enhancement and reduced contrast medium volume achieved by using exponentially decelerated contrast material injection method

被引:63
作者
Bae, KT [1 ]
Tran, HQ [1 ]
Heiken, JP [1 ]
机构
[1] Washington Univ, Sch Med, Mallinckrodt Inst Radiol, St Louis, MO 63110 USA
关键词
aorta; CT; computed tomography (CT); angiography; contrast enhancement; contrast media;
D O I
10.1148/radiol.2313030497
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To investigate in computed tomographic (CT) angiography whether an exponentially decelerated contrast medium injection, as compared with a standard constant-rate injection, can facilitate uniform vascular contrast enhancement with a reduced contrast material volume. MATERIALS AND METHODS: CT angiography of the abdominal aorta was performed in 46 subjects by using an exponentially decelerated injection method: 134 mL of contrast medium was injected for 40 seconds, starting at 4.0 mL/sec and decreasing exponentially to 2.7 mL/sec by the end of the injection. Twenty-one of these subjects also underwent CT angiography with a constant-rate injection: 160 mL of contrast medium was injected for 40 seconds at a constant rate of 4 mL/sec. (a) duration of contrast enhancement achieved within 80% of the peak (80% DCE), (b) SD of the normalized contrast enhancement (SDNCE) measured from the beginning of spiral CT scanning to the time when the enhancement decreased to a level lower than the beginning level, and (c) slope of the enhancement curve calculated by using linear regression analysis. RESULTS: Exponentially decelerated injection resulted in more uniform enhancement. Mean values generated by using exponentially decelerated versus constant-rate injection in 21 paired comparisons were, respectively, 30.8 seconds +/- 5.0 versus 22.6 seconds +/- 7.6 for 80% DCE, 0.052 +/- 0.017 versus 0.086 +/- 0.031 for SDNCE, and 0.47 HU/sec +/- 0.70 versus 2.27 HU/sec +/- 0.87 for slope (P < .001 for all indexes). Compared with the peak enhancement resulting from the constant-rate injection, that resulting from the exponentially decelerated injection was reduced by a mean of 17.2% +/- 10.0. CONCLUSION: Uniform vascular contrast enhancement and reduced contrast medium volume, which are desirable in CT angiography, can be achieved with exponentially decelerated injection. (C) RSNA, 2004.
引用
收藏
页码:732 / 736
页数:5
相关论文
共 8 条
[1]   Multiphasic injection method for uniform prolonged vascular enhancement at CT angiography: Pharmacokinetic analysis and experimental porcine model [J].
Bae, KT ;
Tran, HQ ;
Heiken, JP .
RADIOLOGY, 2000, 216 (03) :872-880
[2]   Peak contrast enhancement in CT and MR angiography: When does it occur and why? Pharmacokinetic study in a porcine model [J].
Bae, KT .
RADIOLOGY, 2003, 227 (03) :809-816
[3]   Perfusion CT with iodinated contrast material [J].
Eastwood, JD ;
Lev, MH ;
Provenzale, JM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 180 (01) :3-12
[4]   Improved uniformity of aortic enhancement with customized contrast medium injection protocols at CT angiography [J].
Fleischmann, D ;
Rubin, GD ;
Bankier, AA ;
Hittmair, K .
RADIOLOGY, 2000, 214 (02) :363-371
[5]   Coronary artery: Quantitative evaluation of normal diameter determined with electron-beam CT compared with cine coronary angiography - Initial experience [J].
Funabashi, N ;
Kobayashi, Y ;
Perlroth, M ;
Rubin, GD .
RADIOLOGY, 2003, 226 (01) :263-271
[6]   EPIDEMIOLOGY OF AORTIC-ANEURYSM IN THE UNITED-STATES [J].
GILLUM, RF .
JOURNAL OF CLINICAL EPIDEMIOLOGY, 1995, 48 (11) :1289-1298
[7]  
HSU RM, 2002, APPL RADIOL S, V31, P33
[8]   Measurement of the aorta and its branches with helical CT [J].
Rubin, GD ;
Paik, DS ;
Johnston, PC ;
Napel, S .
RADIOLOGY, 1998, 206 (03) :823-829