摘要
A superfluid cryostat for an 1 GHz-NMR magnet has been developed and its performance was tested. The magnet was successfully energized up to 21.6 T corresponding to a resonance frequency of 920 MHz this April. Before the 920 MHz operations, the magnet was operated for 5 months at the 900 MHz field to check the long-term reliability of the. cryogenic system. Stable cryogenic performance has been confirmed through this operation. The Hell bath temperature was kept constant below 1.6 K Without any trouble related to the cryostat. The resultant heat load at 1.6 K was 0.55 W. The total helium consumption rate was 800 cc/h.
引用
收藏
页码:1347 / 1350
页数:4
相关论文
共 6 条
[1]   Development and operation of superconducting NMR magnet beyond 900 MHz [J].
Kiyoshi, T ;
Sato, A ;
Takeuchi, T ;
Itoh, K ;
Matsumoto, S ;
Ozaki, O ;
Wada, H ;
Yoshikawa, M ;
Kamikado, T ;
Ito, S ;
Miki, T ;
Hase, T ;
Hamada, M ;
Hayashi, S ;
Kawate, Y ;
Hirose, R .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2001, 11 (01) :2347-2350
[2]  
MATSUMOTO F, UNPUB ADV CRYO ENG, V47
[3]  
MIKI T, 1998, ICEC, V17, P835
[4]  
NAGAI H, UNPUB CRYOGENICS
[5]  
SATO A, 2000, ICEC, V18
[6]  
SATO T, UNPUB PHYS B