Generic serial and parallel on-line direct-injection using turbulent flow liquid chromatography/tandem mass spectrometry

被引:50
作者
Grant, RP [1 ]
Cameron, C [1 ]
Mackenzie-McMurter, S [1 ]
机构
[1] Eli Lily Canada Inc, Lilly Lab Bioanalyt Res, Toronto, ON M1N 2E8, Canada
关键词
D O I
10.1002/rcm.784
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The development of turbulent flow chromatography (TFC) has enabled considerable growth in the utility of on-line direct-injection technologies. TFC has now become established in a large number of varied analytical environments, particularly drug discovery/pharmacokinetics, metabolite profiling, combinatorial library purification, pre-clinical and clinical GLP applications. The utility of turbulent flow technology for in-house pre-clinical and clinical quantitative applications has necessitated extensive valve-cleaning procedures, and consequently lengthy cycle-times, to effectively remove the system carry-over. In-house requirements for assay validation require carry-over less than 20% of the lowest level of quantification (LLOQ), corresponding to 0.02% carry-over for a linear calibration range incorporating 3 orders. A generic turbulent flow chromatography protocol has been developed for drug discovery that incorporates polymeric turbulent flow extraction (cyclone) with C18-based reverse-phase chromatography. Further, multiple wash steps are incorporated within the methodology to meet in-house requirements for carry-over. Selection of novel switching-valve materials based on polyarylethyl ketone (PAEK) and Hastelloy/Valcon E autosampler injection hardware has enabled us to significantly impact the cycle-time required to reduce carry-over. Consequently, optimal usage of switching valves has enabled parallel operation for a generic on-line direct-injection methodology to successfully reduce the total cycle-time. Overall reductions from 4 min per sample to 90 s per sample are shown with comparable data quality using a proprietary target molecule from 0.1-100 ng/mL. This paper describes the hardware configuration and methodologies utilized to perform generic serial and parallel on-line direct-injection using a Turboflow HTLC 2300 system. Copyright (C) 2002 John Wiley Sons, Ltd.
引用
收藏
页码:1785 / 1792
页数:8
相关论文
共 34 条
  • [1] Allanson JP, 1996, RAPID COMMUN MASS SP, V10, P811, DOI 10.1002/(SICI)1097-0231(199605)10:7<811::AID-RCM561>3.0.CO
  • [2] 2-Q
  • [3] Bayliss MK, 2000, RAPID COMMUN MASS SP, V14, P2039, DOI 10.1002/1097-0231(20001115)14:21<2039::AID-RCM130>3.0.CO
  • [4] 2-2
  • [5] de Biasi V, 1999, RAPID COMMUN MASS SP, V13, P1165, DOI 10.1002/(SICI)1097-0231(19990630)13:12<1165::AID-RCM638>3.0.CO
  • [6] 2-4
  • [7] High-speed gradient parallel liquid chromatography/tandem mass spectrometry with fully automated sample preparation for bioanalysis: 30 seconds per sample from plasma
    Deng, Y
    Wu, JT
    Lloyd, TL
    Chi, CL
    Olah, TV
    Unger, SE
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (11) : 1116 - 1123
  • [8] GRANT RP, 2000, P PBA C BAS SWITZ MA
  • [9] Generic method for on-line extraction of drug substances in the presence of biological matrices using turbulent flow chromatography
    Herman, JL
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (05) : 421 - 426
  • [10] Hiller DL, 2000, RAPID COMMUN MASS SP, V14, P2034, DOI 10.1002/1097-0231(20001115)14:21<2034::AID-RCM124>3.0.CO