Using a combination of reference tests to assess the accuracy of a new diagnostic test

被引:3
作者
Alonzo, TA
Pepe, MS
机构
[1] Univ Washington, Dept Biostat, Seattle, WA 98195 USA
[2] Fred Hutchinson Canc Res Ctr, Seattle, WA 98109 USA
关键词
D O I
10.1002/(SICI)1097-0258(19991130)18:22<2987::AID-SIM205>3.0.CO;2-B
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Often the accuracy of a new diagnostic test must be assessed when a perfect gold standard does not exist. Use of an imperfect reference test biases accuracy estimates of the new test. This paper reviews existing approaches to this problem including discrepant resolution and latent class analysis. Deficiencies with these approaches are identified. A new approach is proposed that combines the results of several imperfect reference tests to define a better reference standard. We call this the composite reference standard (CRS). Using the CRS, accuracy can be assessed using multi-stage sampling designs. Maximum likelihood estimates of accuracy and expressions for the variance of sensitivity and specificity are provided. Data from clinical literature on the detection of Chlamydia trachomatis are used to illustrate and compare the different approaches. Advantages of the CRS relative to other approaches include that the CRS is explicitly defined, does not depend on the results of the new test under investigation, and is easy to interpret. Copyright (C) 1999 John Wiley & Sons, Ltd.
引用
收藏
页码:2987 / 3003
页数:17
相关论文
共 52 条
[1]  
ALONZO TA, 1998, 156 U WASH DEP BIOST
[2]   EVALUATING A NEW TEST USING A REFERENCE TEST WITH ESTIMATED SENSITIVITY AND SPECIFICITY [J].
BAKER, SG .
COMMUNICATIONS IN STATISTICS-THEORY AND METHODS, 1991, 20 (09) :2739-2752
[3]   Mycobacterial growth indicator tube for susceptibility testing of Mycobacterium tuberculosis to isoniazid and rifampin [J].
Bergmann, JS ;
Woods, GL .
DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 1997, 28 (03) :153-156
[5]  
CHERNESKY M, 1990, J INFECT DIS, V161, P124
[6]   LIGASE CHAIN-REACTION FOR DETECTION OF NEISSERIA-GONORRHOEAE IN UROGENITAL SWABS [J].
CHING, SF ;
LEE, H ;
HOOK, EW ;
JACOBS, MR ;
ZENILMAN, J .
JOURNAL OF CLINICAL MICROBIOLOGY, 1995, 33 (12) :3111-3114
[7]   Comparisons of cost and accuracy of DNA probe test and culture for the detection of Neisseria gonorrhoeae in patients attending public sexually transmitted disease clinics in Los Angeles County [J].
Ciemins, EL ;
Borenstein, LA ;
Dyer, IE ;
Cordero, E ;
Courtney, JG ;
Harvey, SM ;
Richwald, GA .
SEXUALLY TRANSMITTED DISEASES, 1997, 24 (07) :422-428
[8]   Detection of Chlamydia trachomatis by the Gen-Probe AMPLIFIED Chlamydia Trachomatis Assay (AMP CT) in urine specimens from men and women and endocervical specimens from women [J].
Crotchfelt, KA ;
Pare, B ;
Gaydos, C ;
Quinn, TC .
JOURNAL OF CLINICAL MICROBIOLOGY, 1998, 36 (02) :391-394
[9]   ENZYME IMMUNOASSAYS FOR IGG AND IGM ANTIBODIES TO TOXOPLASMA-GONDII BASED ON ENHANCED CHEMILUMINESCENCE [J].
CROUCH, CF .
JOURNAL OF CLINICAL PATHOLOGY, 1995, 48 (07) :652-657
[10]   Rapid detection and typing of herpes simplex virus DNA in clinical specimens by the Hybrid Capture II signal amplification probe test [J].
Cullen, AP ;
Long, CD ;
Lorincz, AT .
JOURNAL OF CLINICAL MICROBIOLOGY, 1997, 35 (09) :2275-2278