Carotid artery stenting protected with an emboli containment system

被引:100
作者
Whitlow, PL
Lylyk, P
Londero, H
Mendiz, OA
Mathias, K
Jaeger, H
Parodi, J
Schönholz, C
Milei, J
机构
[1] Cleveland Clin Fdn, Dept Cardiol, Cleveland, OH 44195 USA
[2] ENERI, Dept Neuroradiol, Buenos Aires, DF, Argentina
[3] Fdn Favaloro, Dept Cardiol, Buenos Aires, DF, Argentina
[4] Acad Teaching Hosp, Stadt Kliniken Dortmund, Dept Radiol, Dortmund, Germany
[5] Inst Cardiovasc Buenos Aires, Dept Vasc Surg, Buenos Aires, DF, Argentina
[6] Clin Sagrada Familia, Dept Intervent Radiol, Buenos Aires, DF, Argentina
[7] Cardiopsis Conicet, Dept Pathol, Buenos Aires, DF, Argentina
关键词
carotid artery diseases; carotid endarterectomy; stents; stroke;
D O I
10.1161/01.STR.0000013947.17575.B3
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose-Fear of distal embolization and stroke has aroused concern regarding carotid stenting. Devices to protect the cerebral circulation may make carotid stenting safer. Methods-A multidisciplinary study group tested a balloon occlusion-aspiration emboli entrapment device in conjunction with carotid stenting. The device consists of an elastomeric balloon on a steerable wire with a detachable adapter that inflates and deflates the distal temporary occlusion balloon. An aspiration catheter is used to remove trapped emboli after stenting and before occlusion balloon deflation. Results-Seventy-five patients with severe internal carotid artery stenosis were treated with stents deployed with this cerebrovasculature protection system. All 75 patients (100%) had grossly visible particulate material aspirated, and all were treated successfully without major or minor stroke or death at 30 days. Preintervention stenosis was 81 +/- 10%, and residual stenosis was 5 +/- 7%. Nine patients (12%) had angiographic evidence of thrombus before intervention, but no patient had thrombus or vessel cutoff after the procedure. Four patients (5%) developed transient neurological symptoms during protection balloon occlusion. but symptoms resolved with balloon deflation. The 22 to 667 particles aspirated per patient ranged from 3.6 to 5262 mum in maximum diameter (mean, 203 +/- 256 mum). These particles included fibrous plaque debris, lipid or cholesterol vacuoles, and calcific plaque fragments. Conclusions-Protected carotid stenting was per-formed successfully and safely in this study early in the experience with cerebrovascular protection devices. Particulate emboli are frequent with stenting, and cerebral protection will likely be necessary to minimize stroke. Randomized trials comparing protected carotid stenting with endarterectomy are warranted.
引用
收藏
页码:1308 / 1314
页数:7
相关论文
共 31 条
  • [1] BAIM DS, 2000, TRANSC CARD THER C O
  • [2] BAKER JD, 1987, SURG CEREBROVASCULAR, P703
  • [3] ANGIOPLASTY-INDUCED DISSECTIONS IN HUMAN ILIAC ARTERIES - MANAGEMENT WITH PALMAZ BALLOON-EXPANDABLE INTRALUMINAL STENTS
    BECKER, GJ
    PALMAZ, JC
    REES, CR
    EHRMAN, KO
    LALKA, SG
    DALSING, MC
    CIKRIT, DF
    MCLEAN, GK
    BURKE, DR
    RICHTER, GM
    NOELDGE, G
    GARCIA, O
    WALLER, BF
    CASTANEDAZUNIGA, WR
    [J]. RADIOLOGY, 1990, 176 (01) : 31 - 38
  • [4] Concern about safety of carotid angioplasty
    Beebe, HG
    Archie, JP
    Baker, WH
    Barnes, RW
    Becker, GJ
    Bernstein, EF
    Brener, B
    Clagett, GP
    Clowes, AW
    Cooke, JP
    Creager, MA
    Cronenwett, JL
    Dake, M
    DeWeese, JA
    Fogarty, TJ
    Freischlag, JA
    Goldstone, J
    Greenfield, LJ
    Hertzer, NR
    Hobson, RW
    Joyce, JW
    Katzen, BT
    LoGerfo, FW
    Mohr, JP
    Moore, WS
    Najafi, H
    Ricotta, JJ
    Riles, TS
    Ring, EJ
    Robertson, J
    Rutherford, RB
    Sos, T
    Stanley, JC
    Strandness, DE
    Sumner, DS
    Toole, J
    Towne, JB
    Veith, FJ
    Whittemore, AD
    Yao, JST
    Zarins, CK
    [J]. STROKE, 1996, 27 (02) : 197 - 198
  • [5] Carotid stenting and angioplasty - A statement for healthcare professionals from the Councils on Cardiovascular Radiology, Stroke, Cardio-thoracic and Vascular Surgery, Epidemiology and Prevention, and Clinical Cardiology, American Heart Association
    Bettmann, MA
    Katzen, BT
    Whisnant, J
    Brant-Zawadzki, M
    Broderick, JP
    Furlan, AJ
    Hershey, LA
    Howard, V
    Kuntz, R
    Loftus, CM
    Pearce, W
    Roberts, A
    Roubin, G
    [J]. CIRCULATION, 1998, 97 (01) : 121 - 123
  • [6] Prevention of distal embolization during saphenous vein graft lesion angioplasty - Experience with a new temporary occlusion and aspiration system
    Carlino, M
    De Gregorio, J
    Di Mario, C
    Anzuini, A
    Airoldi, F
    Albiero, R
    Briguori, C
    Dharmadhikari, A
    Sheiban, I
    Colombo, A
    [J]. CIRCULATION, 1999, 99 (25) : 3221 - 3223
  • [7] A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE
    FISCHMAN, DL
    LEON, MB
    BAIM, DS
    SCHATZ, RA
    SAVAGE, MP
    PENN, I
    DETRE, K
    VELTRI, L
    RICCI, D
    NOBUYOSHI, M
    CLEMAN, M
    HEUSER, R
    ALMOND, D
    TEIRSTEIN, PS
    FISH, RD
    COLOMBO, A
    BRINKER, J
    MOSES, J
    SHAKNOVICH, A
    HIRSHFELD, J
    BAILEY, S
    ELLIS, S
    RAKE, R
    GOLDBERG, S
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) : 496 - 501
  • [8] Henry M, 1998, J ENDOVASC SURG, V5, P293, DOI 10.1583/1074-6218(1998)005<0293:AASOTE>2.0.CO
  • [9] 2