An Efficient and Robust Hybrid Damper for LCL-or LLCL-Based Grid-Tied Inverter With Strong Grid-Side Harmonic Voltage Effect Rejection

被引:147
作者
Liu, Yuan [1 ]
Wu, Weimin [2 ]
He, Yuanbin [3 ]
Lin, Zhe [4 ]
Blaabjerg, Frede [5 ,6 ]
Chung, Henry Shu-Hung [3 ]
机构
[1] Shanghai Maritime Univ, Res Inst Elect Automat, Shanghai 201306, Peoples R China
[2] Shanghai Maritime Univ, Dept Elect Engn, Shanghai 201306, Peoples R China
[3] City Univ Hong Kong, Dept Elect Engn, Coll Sci & Engn, Ctr Smart Energy Convers & Utilizat Res CSCR, Kowloon, Hong Kong, Peoples R China
[4] Shanghai Edrive Co Ltd, Shanghai 200240, Peoples R China
[5] Aalborg Univ, Dept Energy Technol, Fac Engn, DK-9220 Aalborg, Denmark
[6] Aalborg Univ, Fac Sci, DK-9220 Aalborg, Denmark
基金
美国国家科学基金会;
关键词
Background harmonic voltage (BHV); grid impedance variation; harmonic rejection ability; LCL-filter; LLCL-filter; notch filter; RC parallel damper; robustness; single loop; IMPEDANCE ESTIMATION; CONNECTED INVERTER; STABILITY ANALYSIS; DAMPING METHOD; POWER FILTER; DESIGN; PERFORMANCE; OPTIMIZATION; CONVERTERS; IMPROVE;
D O I
10.1109/TIE.2015.2478738
中图分类号
TP [自动化技术、计算机技术];
学科分类号
080201 [机械制造及其自动化];
摘要
A high-order (LCL or LLCL) powerfilterwith a small grid-side inductor is becoming more preferred for a grid-tied inverter due to less total inductance and reduced costs. In a microgrid, the background harmonic voltage (BHV) may distort the injected currents of the grid-tied inverters. In order to resist the effect of the BHV, a feed-forward voltage compensator and a proportional resonant regulator with harmonic compensation are often adopted. However, they still have their own limitations, particularly when there are higher order BHVs at the point of common coupling and when the equivalent grid impedance widely varies due to the different numbers of grid-tied inverters in parallel. Thus, an extra damper should be inserted to keep the system stable. In this paper, the control bandwidth limitation of a multiloop control active damping (AD) method is analyzed and illustrated by the capacitor-current-feedback AD. Based on this, a single-loop current control with a hybrid damper is proposed for a single-phase LCL-or LLCL-filter-based grid-tied inverter. A step-by-step design of the controller method is also introduced in detail. Experiments on a 2-kW prototype fully demonstrate the strong robustness of the stability and the high harmonic rejection ability of the inverter using the proposed control method.
引用
收藏
页码:926 / 936
页数:11
相关论文
共 45 条
[1]
A digital controlled PV-inverter with grid impedance estimation for ENS detection [J].
Asiminoaei, L ;
Teodorescu, R ;
Blaabjerg, F ;
Borup, U .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2005, 20 (06) :1480-1490
[2]
Implementation and test of an online embedded grid impedance estimation technique for PV inverters [J].
Asiminoaei, L ;
Teodorescu, R ;
Blaabjerg, F ;
Borup, U .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2005, 52 (04) :1136-1144
[3]
High-Order Vector Control of Grid-Connected Voltage-Source Converters With LCL-Filters [J].
Bahrani, Behrooz ;
Vasiladiotis, Michail ;
Rufer, Alfred .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2014, 61 (06) :2767-2775
[4]
Step-by-Step Controller Design for LCL-Type Grid-Connected Inverter with Capacitor-Current-Feedback Active-Damping [J].
Bao, Chenlei ;
Ruan, Xinbo ;
Wang, Xuehua ;
Li, Weiwei ;
Pan, Donghua ;
Weng, Kailei .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (03) :1239-1253
[5]
Filter Optimization for Grid Interactive Voltage Source Inverters [J].
Channegowda, Parikshith ;
John, Vinod .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2010, 57 (12) :4106-4114
[6]
Filter-Based Active Damping of Voltage Source Converters With LCL Filter [J].
Dannehl, Joerg ;
Liserre, Marco ;
Fuchs, Friedrich Wilhelm .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2011, 58 (08) :3623-3633
[7]
Composite Nonlinear Feedback Control and Stability Analysis of a Grid-Connected Voltage Source Inverter With LCL Filter [J].
Eren, Suzan ;
Pahlevaninezhad, Majid ;
Bakhshai, Alireza ;
Jain, Praveen K. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2013, 60 (11) :5059-5074
[8]
High-Performance Voltage Regulation of Current Source Inverters [J].
Grogan, Sorrell Alistair Shield ;
Holmes, Donald Grahame ;
McGrath, Brendan Peter .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2011, 26 (09) :2439-2448
[9]
Two Degrees of Freedom Active Damping Technique for LCL Filter-Based Grid Connected PV Systems [J].
Hanif, Moin ;
Khadkikar, Vinod ;
Xiao, Weidong ;
Kirtley, James L., Jr. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2014, 61 (06) :2795-2803
[10]
Minimal Invasive Equivalent Grid Impedance Estimation in Inductive-Resistive Power Networks Using Extended Kalman Filter [J].
Hoffmann, Nils ;
Fuchs, Friedrich Wilhelm .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (02) :631-641