Tomographic imaging of the angular-dependent coherent-scatter cross section

被引:43
作者
Westmore, MS
Fenster, A
Cunningham, IA
机构
[1] UNIV WESTERN ONTARIO,DEPT MED BIOPHYS,LONDON,ON N6A 5C1,CANADA
[2] LONDON HLTH SCI CTR VICTORIA,DEPT DIAGNOST RADIOL,LONDON,ON N6A 4G5,CANADA
[3] UNIV WESTERN ONTARIO,DEPT MED BIOPHYS,LONDON,ON N6A 5C1,CANADA
关键词
coherent scatter; computed tomography; x-ray diffraction; bone-mineral content (BMC); material-specific imaging;
D O I
10.1118/1.597917
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A new special-purpose computed tomographic (CT) imaging system is described which produces images based on measurements of the low-angle (0 - 10 degrees) x-ray diffraction properties of an object. Low-angle scatter in the diagnostic x-ray energy range is dominated by coherent scatter, and the system uses first-generation CT geometry to acquire a diffraction pattern for each pencil beam. The patterns are used to reconstruct a series of images which represent the coherent-scatter intensity at a series of scatter angles. To demonstrate the potential of coherent-scatter CT (CSCT), the scanner has been built and used to image a phantom consisting of a water-filled Lucite cylinder containing rods of polyethylene, Lucite, polycarbonate, and nylon. in this paper, the system is described and a sequence of CSCT images of this phantom is shown. Coherent-scatter cross sections of these materials are generated for each pixel from this sequence of images and compared with cross sections measured separately. The resulting excellent agreement shows that the angular-dependent coherent-scatter cross section can be accurately imaged in a tomographic slice through an object. These cross sections give material-specific information about the object. The long-term goal of this research is to make measurements of bone-mineral content for every pixel in a tomographic slice (C) 1997 American Association of Physicists in Medicine.
引用
收藏
页码:3 / 10
页数:8
相关论文
共 16 条
[1]  
BARRETT HH, 1981, RADIOLOGICAL IMAGING, P379
[2]   NOISE AND CONTRAST DETECTION IN COMPUTED-TOMOGRAPHY IMAGES [J].
FAULKNER, K ;
MOORES, BM .
PHYSICS IN MEDICINE AND BIOLOGY, 1984, 29 (04) :329-339
[3]   STATISTICAL LIMITATIONS IN COMPUTED TOMOGRAPHY [J].
GORE, JC ;
TOFTS, PS .
PHYSICS IN MEDICINE AND BIOLOGY, 1978, 23 (06) :1176-1182
[4]   ENERGY-DISPERSIVE X-RAY-DIFFRACTION TOMOGRAPHY [J].
HARDING, G ;
NEWTON, M ;
KOSANETZKY, J .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (01) :33-41
[5]   STATUS AND OUTLOOK OF COHERENT-X-RAY SCATTER IMAGING [J].
HARDING, G ;
KOSANETZKY, J .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1987, 4 (05) :933-944
[6]   X-RAY-DIFFRACTION COMPUTED-TOMOGRAPHY [J].
HARDING, G ;
KOSANETZKY, J ;
NEITZEL, U .
MEDICAL PHYSICS, 1987, 14 (04) :515-525
[7]   ELASTIC SCATTER COMPUTED-TOMOGRAPHY [J].
HARDING, G ;
KOSANETZKY, J ;
NEITZEL, U .
PHYSICS IN MEDICINE AND BIOLOGY, 1985, 30 (02) :183-186
[8]  
HUESMAN RH, 1977, DONNER ALGORITHMS RE
[9]   COHERENT SCATTERING AND THE ASSESSMENT OF MINERAL CONCENTRATION IN TRABECULAR BONE [J].
KERR, SA ;
KOURIS, K ;
WEBBER, CE ;
KENNETT, TJ .
PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (06) :1037-1047
[10]   X-RAY-DIFFRACTION MEASUREMENTS OF SOME PLASTIC MATERIALS AND BODY-TISSUES [J].
KOSANETZKY, J ;
KNOERR, B ;
HARDING, G ;
NEITZEL, U .
MEDICAL PHYSICS, 1987, 14 (04) :526-532