Statically equivalent load and support conditions produce different hip joint contact pressures and periacetabular strains

被引:50
作者
Bay, BK
Hamel, AJ
Olson, SA
Sharkey, NA
机构
[1] Orthopaedic Reasearch Laboratories, University of California, Davis School of Medicine, Sacramento, CA 95817
关键词
hip joint; joint reaction force; contact pressure; Fuji film; strain;
D O I
10.1016/S0021-9290(96)00120-0
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The hip is a common site of orthopaedic trauma and disease, and considerable research has been directed toward understanding the development of contact pressures within the joint. Virtually all experimental studies to date have employed proximal Femurs compressed along the joint reaction force vector into acetabulae explanted from cadaver pelves. This approach presumes that deformations of the acetabulum are highly localized, and that the pelvis is functionally a rigid body. We have developed a methodology that uses intact pelves loaded through simulation of the abductor mechanism. A direct comparison of the two techniques revealed significantly different joint contact characteristics and periacetabular strains. Fuji film measurements of contact area and pressure were more widely distributed across the acetabulum for the intact pelvis, with significant pressure development in anterior and posterior regions. Contact patterns in the explanted acetabulae were concentrated in the superior portion of the joint. Principal strains from three rosette gages placed near the acetabular rim were also significantly different for the two testing techniques, but were not substantially altered by the presence of Fuji film within the joint. The results indicate that deformation of the entire pelvis and the manner in which loads are applied significantly affect development of contact pressures within the hip joint, and that Fuji film is a suitable technique for recording those patterns. Copyright (C) 1996 Elsevier Science Ltd.
引用
收藏
页码:193 / 196
页数:4
相关论文
共 19 条
[1]   CONTACT PRESSURES IN THE HUMAN HIP-JOINT [J].
AFOKE, NYP ;
BYERS, PD ;
HUTTON, WC .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1987, 69 (04) :536-541
[2]   A STEREOPHOTOGRAMMETRIC METHOD FOR DETERMINING IN-SITU CONTACT AREAS IN DIARTHROIDAL JOINTS, AND A COMPARISON WITH OTHER METHODS [J].
ATESHIAN, GA ;
KWAK, SD ;
SOSLOWSKY, LJ ;
MOW, VC .
JOURNAL OF BIOMECHANICS, 1994, 27 (01) :111-124
[3]   STRESS ON THE ARTICULAR SURFACE OF THE HIP-JOINT IN HEALTHY-ADULTS AND PERSONS WITH IDIOPATHIC OSTEOARTHROSIS OF THE HIP-JOINT [J].
BRINCKMANN, P ;
FROBIN, W ;
HIERHOLZER, E .
JOURNAL OF BIOMECHANICS, 1981, 14 (03) :149-156
[4]   INVITRO CONTACT STRESS DISTRIBUTIONS IN THE NATURAL HUMAN HIP [J].
BROWN, TD ;
SHAW, DT .
JOURNAL OF BIOMECHANICS, 1983, 16 (06) :373-384
[5]  
Bullough P, 1973, J Bone Joint Surg Br, V55, P746
[6]   A POST-MORTEM STUDY OF HIP JOINT . INCLUDING PREVALENCE OF FEATURES OF RIGHT SIDE [J].
BYERS, PD ;
CONTEPOMI, CA ;
FARKAS, TA .
ANNALS OF THE RHEUMATIC DISEASES, 1970, 29 (01) :15-+
[7]   ANATOMY OF THE ABDUCTOR MUSCLES OF THE HIP AS STUDIED BY COMPUTED-TOMOGRAPHY [J].
CLARK, JM ;
HAYNOR, DR .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1987, 69A (07) :1021-1031
[8]   LOAD-TRANSFER ACROSS THE PELVIC BONE [J].
DALSTRA, M ;
HUISKES, R .
JOURNAL OF BIOMECHANICS, 1995, 28 (06) :715-724
[9]   THE EFFECT OF LAPAROTOMY AND EXTERNAL FIXATOR STABILIZATION ON PELVIC VOLUME IN AN UNSTABLE PELVIC INJURY [J].
GHANAYEM, AJ ;
WILBER, JH ;
LIEBERMAN, JM ;
MOTTA, AO .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1995, 38 (03) :396-401
[10]  
GOODFELLOW J, 1977, J BONE JOINT SURG BR, V59, P446, DOI 10.1302/0301-620X.59B4.925055