Flow cytometry analysis of the effects of pre-immersion on the biocompatibility of glass-reinforced hydroxyapatite plasma-sprayed coatings

被引:26
作者
Ferraz, MP
Knowles, JC
Olsen, I
Monteiro, FJ
Santos, JD
机构
[1] UCL, Eastman Dent Inst, Dept Periodontol, London WC1X 8LD, England
[2] UCL, Eastman Dent Inst, Dept Biomat, London WC1X 8LD, England
[3] Univ Porto, FEUP, Dept Met Engn, P-4099 Oporto, Portugal
[4] Inst Biomed Engn, Lab Biomat, P-4150 Oporto, Portugal
关键词
biocompatibility; flow cytometry; pre-immersion; glass-reinforced hydroxyapatite;
D O I
10.1016/S0142-9612(99)00249-5
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Multilayered coatings composed of mixtures of HA and P(2)O(5)-based bioactive glasses are of potential clinical benefit in orthopaedic and dental surgery. Pre-immersion of these materials has been reported to further enhance their efficacy in vivo, although the precise biological effects of this treatment are not yet known. In this study we have therefore prepared double-layer plasma-sprayed coatings and evaluated the effects of pre-immersion on the growth and function of human osteosarcoma cells in vitro, using the MTT assay and flow cytometry analysis, respectively. The results showed that the increase in numbers of viable cells was the same or elevated following incubation on the pre-immersed HA and glass-reinforced HA coatings compared with the non-immersed materials. In addition, the expression of bone sialoprotein and fibronectin, two key connective tissue antigens, was up-regulated in cultures grown on the pre-immersed surfaces compared with the non-treated materials. Moreover, cell numbers and antigen expression both improved as the proportion of glass increased, particularly in the pre-immersed samples. Our findings thus suggest that the immersion treatment of these materials appeared to improve the response of these bone-like cells. (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:813 / 820
页数:8
相关论文
共 42 条
[1]  
[Anonymous], BIOCERAMICS
[2]  
BURNIE F, 1983, CERAMICS SURG, P177
[3]  
BURNIE J, 1983, CERAMICS SURG, P169
[4]   A comparative study of the use of colorimetric assays in the assessment of biocompatibility [J].
Clifford, CJ ;
Downes, S .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1996, 7 (10) :637-643
[5]   ARE MG-63 AND HOS TE85 HUMAN OSTEOSARCOMA CELL-LINES REPRESENTATIVE MODELS OF THE OSTEOBLASTIC PHENOTYPE [J].
CLOVER, J ;
GOWEN, M .
BONE, 1994, 15 (06) :585-591
[6]  
CONISH H, 1981, SCI MED APPL HYDROXY
[7]   SIMULTANEOUS MEASUREMENT OF 2 CELLULAR ANTIGENS AND DNA USING FLUORESCEIN-ISOTHIOCYANATE, R-PHYCOERYTHRIN, AND PROPIDIUM IODIDE ON A STANDARD FACSCAN [J].
CORVER, WE ;
CORNELISSE, CJ ;
FLEUREN, GJ .
CYTOMETRY, 1994, 15 (02) :117-128
[8]   COMPARISON OF THE EARLY PRODUCTION OF EXTRACELLULAR-MATRIX ON DENSE HYDROXYAPATITE AND HYDROXYAPATITE-COATED TITANIUM IN CELL AND ORGAN-CULTURE [J].
COURTENEYHARRIS, RG ;
KAYSER, MV ;
DOWNES, S .
BIOMATERIALS, 1995, 16 (06) :489-495
[9]   Mineralization and the expression of matrix proteins during in vivo bone development [J].
Cowles, EA ;
DeRome, ME ;
Pastizzo, G ;
Brailey, LL ;
Gronowicz, GA .
CALCIFIED TISSUE INTERNATIONAL, 1998, 62 (01) :74-82
[10]   THE ULTRASTRUCTURE OF THE BONE HYDROXYAPATITE INTERFACE INVITRO [J].
DEBRUIJN, JD ;
KLEIN, CPAT ;
DEGROOT, K ;
VANBLITTERSWIJK, CA .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1992, 26 (10) :1365-1382