Muskuloskeletal MR imaging at 3.0 T: current status and future perspectives

被引:35
作者
Bolog, Nicolae [1 ]
Nanz, Daniel [1 ]
Weishaupt, Dominik [1 ]
机构
[1] Univ Hosp, Inst Diagnost Radiol, CH-8091 Zurich, Switzerland
关键词
MR imaging; 3; Tesla; musculoskeletal imaging;
D O I
10.1007/s00330-006-0184-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Magnetic resonance (MR) imaging has become an important diagnostic tool in evaluation of the musculoskeletal system. While most examinations are currently performed at magnetic field strengths of 1.5 T or lower, whole-body MR systems operating at 3.0 T have recently become available for clinical use. The higher field strengths promise various benefits, including increased signal-to-noise ratios, enhanced T2* contrast, increased chemical shift resolution, and most likely a better diagnostic performance in various applications. However, the changed T1, T2, and T2* relaxation times, the increased resonance-frequency differences caused by susceptibility and chemical-shift differences, and the increased absorption of radiofrequency (RF) energy by the tissues pose new challenges and/or offer new opportunities for imaging at 3.0 T compared to 1.5 T. Some of these issues have been successfully addressed only in the very recent past. This review discusses technical aspects of 3.0 T imaging as far as they have an impact on clinical routine. An overview of the current data is presented, with a focus on areas where 3.0 T promises equivalent or improved performance compared 1.5 T or lower field strengths.
引用
收藏
页码:1298 / 1307
页数:10
相关论文
共 59 条
[1]
Sensitivity of T2-weighted FSE sequences towards physiological iron depositions in normal brains at 1.5 and 3.0 T [J].
Allkemper, T ;
Schwindt, W ;
Maintz, D ;
Heindel, W ;
Tombach, B .
EUROPEAN RADIOLOGY, 2004, 14 (06) :1000-1004
[2]
BAUER J, 2005, P ISMRM MIAM
[3]
Reduced RF power without blurring: Correcting for modulation of refocusing flip angle in FSE sequences [J].
Busse, RF .
MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (05) :1031-1037
[4]
Signal-to-noise ratio and absorbed power as functions of main magnetic field strength, and definition of "90°" RF pulse for the head in the birdcage coil [J].
Collins, CM ;
Smith, MB .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (04) :684-691
[5]
COX IH, 1995, AM J NEURORADIOL, V16, P1367
[6]
DEZANCHE N, 2005, P ISMRM MIAM
[7]
MUSCULOSKELETAL MR-IMAGING AT 4 T AND AT 1.5 T - COMPARISON OF RELAXATION-TIMES AND IMAGE-CONTRAST [J].
DUEWELL, SH ;
CECKLER, TL ;
ONG, K ;
WEN, H ;
JAFFER, FA ;
CHESNICK, SA ;
BALABAN, RS .
RADIOLOGY, 1995, 196 (02) :551-555
[8]
FREQUENCY-SHIFT ARTIFACTS IN MR IMAGING [J].
DWYER, AJ ;
KNOP, RH ;
HOULT, DI .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (01) :16-18
[9]
A comparison of conventional spin-echo and turbo spin-echo imaging of soft tissues adjacent to orthopedic hardware [J].
Eustace, S ;
Jara, H ;
Goldberg, R ;
Fenlon, H ;
Mason, M ;
Melhem, ER ;
Yucel, EK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (02) :455-458
[10]
In vivo high-resolution MR imaging of the carpal tunnel at 8.0 tesla [J].
Farooki, S ;
Ashman, CJ ;
Yu, JS ;
Abduljalil, A ;
Chakeres, D .
SKELETAL RADIOLOGY, 2002, 31 (08) :445-450