Mechanical characteristics of impacted morsellised bone grafts used in revision of total hip arthroplasty

被引:68
作者
Giesen, EBW
Lamerigts, NMP
Verdonschot, N
Buma, P
Schreurs, BW
Huiskes, R
机构
[1] Univ Nijmegen, Orthopaed Res Lab, NL-6500 HB Nijmegen, Netherlands
[2] Univ Nijmegen, Dept Orthopaed, NL-6500 HB Nijmegen, Netherlands
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 1999年 / 81B卷 / 06期
关键词
D O I
10.1302/0301-620X.81B6.8742
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The use of impacted, morsellised bone grafts has I become popular in revision total hip arthroplasty (THA), The initial stability of the reconstruction and the effectiveness of any subsequent pr(,cess of revitalisation and incorporation will depend on the mechanical integrity of the graft. Our aim in this study was to document the time-dependent mechanical properties of the morsellised graft. This information is useful in clinical application of the graft, in studies of migration of the implant and, in the design of the joint. We used 16 specimens of impacted, morsellised cancellous bone from the sternum of goats to assess the mechanical properties by confined compression creep tests, Consideration of the graft material as a porous, permeable solid, filled with fluid, allowed determination of the compressive modulus of the matrix, and its permeability to fluid flow. In all specimens the compression tests showed large, irreversible deformations, caused by how-independent creep behaviour as a result of rolling and sliding of the bone chips. The mean permeability was 8.82 *10(-12) m(4)/Ns (sD 43%), and the compressive modulus was 38.7 MPa (sD 34%). No correlation was found between the apparent density and the permeability or between the apparent density and the compressive modulus. The irreversible deformations in the graft could be captured by a creep law for which the parameters were quantified. We conclude that ire clinical use the graft is bound to be subject to permanent deformation after operation, The permeability of the material is relatively high compared with, for example, human cartilage, The confined compression modulus is relatively low compared wills cancellous bone of the same apparent density, Designs of prostheses used in revision surgery must accommodate the viscoelastic and permanent deformations in the graft without causing loosening at the interface.
引用
收藏
页码:1052 / 1057
页数:6
相关论文
共 19 条
  • [1] VARIATIONS IN THE INTRINSIC MECHANICAL PROTERTIES OF HUMAN ARTICULAR-CARTILAGE WITH AGE, DEGENERATION, AND WATER-CONTENT
    ARMSTRONG, CG
    MOW, VC
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1982, 64 (01) : 88 - 94
  • [2] BRODT MD, 1997, T ORS, V43, P807
  • [3] COMPRESSIVE BEHAVIOR OF BONE AS A 2-PHASE POROUS STRUCTURE
    CARTER, DR
    HAYES, WC
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1977, 59 (07) : 954 - 962
  • [4] ELTING JJ, 1995, CLIN ORTHOP RELAT R, P159
  • [5] IMPACTED CANCELLOUS ALLOGRAFTS AND CEMENT FOR REVISION TOTAL HIP-ARTHROPLASTY
    GIE, GA
    LINDER, L
    LING, RSM
    SIMON, IP
    SLOOFF, TJJH
    TIMPERLEY, AJ
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (01): : 14 - 21
  • [6] HUBBLE MJW, 1996, T EORS, V6, P43
  • [7] REVISION TOTAL HIP-ARTHROPLASTY WITH THE BIAS FEMORAL COMPONENT - 3 TO 6-YEAR RESULTS
    HUSSAMY, O
    LACHIEWICZ, PF
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1994, 76A (08) : 1137 - 1148
  • [8] INTERSPECIES VARIATION OF COMPRESSIVE BIOMECHANICAL PROPERTIES OF THE MENISCUS
    JOSHI, MD
    SUH, JK
    MARUI, T
    WOO, SLY
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1995, 29 (07): : 823 - 828
  • [9] KUIPER JH, 1996, T EORS, V6, P45
  • [10] BIPHASIC CREEP AND STRESS-RELAXATION OF ARTICULAR-CARTILAGE IN COMPRESSION - THEORY AND EXPERIMENTS
    MOW, VC
    KUEI, SC
    LAI, WM
    ARMSTRONG, CG
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1980, 102 (01): : 73 - 84