Accurate estimation of the fisher information matrix for the PET image reconstruction problem

被引:34
作者
Li, QZ
Asma, E
Qi, JY
Bading, JR
Leahy, RM [1 ]
机构
[1] Univ So Calif, Inst Signal & Image Proc, Los Angeles, CA 90089 USA
[2] Univ Calif Berkeley, Ctr Funct Imaging, LBL, Berkeley, CA 94270 USA
[3] Univ So Calif, PET Imaging Sci Ctr, Los Angeles, CA 90033 USA
关键词
Fisher information matrix; image reconstruction; PET; uniform resolution;
D O I
10.1109/TMI.2004.833202
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The Fisher information matrix (FIM) plays a key role in the analysis and applications of statistical image reconstruction methods based on Poisson data models. The elements of the FIM are a function of the reciprocal of the mean values of sinogram elements. Conventional plug-in FIM estimation methods do not work well at low counts, where the FIM estimate is highly sensitive to the reciprocal mean estimates at individual detector pairs. A generalized error look-up table (GELT) method is developed to estimate the reciprocal of the mean of the sinogram data. This approach is also extended to randoms precorrected data. Based on these techniques, an accurate FIM estimate is obtained for both Poisson and randoms precorrected data. As an application, the new GELT method is used to improve resolution uniformity and achieve near-uniform image resolution in low count situations.
引用
收藏
页码:1057 / 1064
页数:8
相关论文
共 18 条
[1]  
AHN S, 2003, P IEEE NUCL SCI S ME
[2]  
BARRETT HH, 1995, J OPT SOC AM A, V12
[3]   Covariance approximation for fast and accurate computation of channelized Hotelling observer statistics [J].
Bonetto, P ;
Qi, JY ;
Leahy, RM .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (04) :1567-1572
[4]   Mean and variance of implicitly defined biased estimators (such as penalized maximum likelihood): Applications to tomography [J].
Fessler, JA .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 1996, 5 (03) :493-506
[5]   Spatial resolution properties of penalized-likelihood image reconstruction: Space-invariant tomographs [J].
Fessler, JA ;
Rogers, WL .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 1996, 5 (09) :1346-1358
[6]   3-D PHANTOM TO SIMULATE CEREBRAL BLOOD-FLOW AND METABOLIC IMAGES FOR PET [J].
HOFFMAN, EJ ;
CUTLER, PD ;
DIGBY, WM ;
MAZZIOTTA, JC .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (02) :616-620
[7]   Effects of SPECT collimation and system geometry on classification tasks related to Parkinson's disease [J].
Kijewski, MF ;
Moore, SC ;
Jadvar, H ;
Zimmerman, RE ;
Müller, SP .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (03) :734-738
[8]  
Kijewski MF, 1997, J NUCL MED, V38, P151
[9]   Resolution and noise properties of MAP reconstruction for fully 3-D PET [J].
Qi, JY ;
Leahy, RM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (05) :493-506
[10]   High-resolution 3D Bayesian image reconstruction using the microPET small-animal scanner [J].
Qi, JY ;
Leahy, RM ;
Cherry, SR ;
Chatziioannou, A ;
Farquhar, TH .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (04) :1001-1013