The precision and accuracy of templating the size of unicondylar knee arthroplasty

被引:25
作者
Kasis, AG [1 ]
Pacheco, RJ
Hekal, W
Farhan, MJ
Smith, DM
Ali, AM
机构
[1] Bassetlaw Dist Gen Hosp, Worksop S81 0BD, England
[2] Med Coll Georgia, Off Biostat & Bioinformat, Augusta, GA 30912 USA
[3] Oldchurch Hosp, Romford RM7 0BE, Essex, England
关键词
precision; accuracy; reliability; reproducibility; template; unicondylar knee arthroplasty;
D O I
10.1016/j.knee.2004.06.003
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
In trauma and joint arthroplasty, preoperative templating is an important step that can help in the selection of implant size, position and alignment. Although the precision (reproducibility) of templating in unicondylar knee arthroplasty has been assessed previously, the accuracy has never been studied. Our aim is to assess the precision and accuracy of using the templating system for one commonly used unicondylar knee arthroplasty, ALPHANORM(R) design (Alphanorm Medizintechnik, Germany). Eight observers used the templating system to estimate the size of the unicondylar knee prosthesis ALPHANORM(R) in 29 randomly selected patients with osteoarthritis. The observers, who all were orthopaedic surgeons with two different levels of experience, worked independently and repeated their measurements 2 weeks later. All the patients subsequently underwent unicondylar knee replacements, and the actual size of the femur and tibia was assessed intra-operatively without any knowledge of the template sizes. Our results revealed a high level of intra-observer reproducibility. However, the inter-observer reproducibility and the accuracy all were poor. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:395 / 398
页数:4
相关论文
共 12 条
[1]
BOTHRA V, IN PRESS J ARTHROPLA
[2]
Capello W N, 1986, Instr Course Lect, V35, P249
[3]
Charnley J., 1979, LOW FRICTION ARTHROP, DOI [10.1007/978-3-642-67013-8, DOI 10.1007/978-3-642-67013-8]
[4]
CLARKE IC, 1976, CLIN ORTHOP RELAT R, P83
[6]
The value of preoperative planning for total hip arthroplasty [J].
Eggli, S ;
Pisan, M ;
Muller, ME .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (03) :382-390
[7]
Kinemax total knee arthroplasty - Trial by template [J].
Heal, J ;
Blewitt, N .
JOURNAL OF ARTHROPLASTY, 2002, 17 (01) :90-94
[8]
Knight J L, 1992, J Arthroplasty, V7 Suppl, P403, DOI 10.1016/S0883-5403(07)80031-3
[9]
MEASUREMENT OF OBSERVER AGREEMENT FOR CATEGORICAL DATA [J].
LANDIS, JR ;
KOCH, GG .
BIOMETRICS, 1977, 33 (01) :159-174
[10]
MULLER ME, 1992, CLIN ORTHOP RELAT R, P12