A confident decision support system for interpreting electrocardiograms

被引:41
作者
Holst, H
Ohlsson, M
Peterson, C
Edenbrandt, L
机构
[1] Lund Univ, Dept Clin Physiol, Lund, Sweden
[2] Lund Univ, Dept Theoret Phys, Lund, Sweden
来源
CLINICAL PHYSIOLOGY | 1999年 / 19卷 / 05期
关键词
computer-assisted electrocardiography; diagnosis; myocardial infarction; neural networks (computer);
D O I
10.1046/j.1365-2281.1999.00195.x
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Computer-aided interpretation of electrocardiograms (ECGs) is widespread but many physicians hesitate to rely on the computer, because the advice is presented without information about the confidence of the advice. The purpose of this work was to develop a method to validate the advice of a computer by estimating the error of an artificial neural network output. A total of 1249 ECGs, recorded with computerized electrocardiographs, on patients who had undergone diagnostic cardiac catheterization were studied. The material consisted of two groups, 414 patients with and 835 without anterior myocardial infarction. The material was randomly divided into three data sets. The first set was used to train an artificial neural network for the diagnosis of anterior infarction. The second data set was used to calculate the error of the network outputs. The fast data set was used to test the network performance and to estimate the error of the network outputs. The performance of the neural network, measured as the area under the receiver operating characteristic (ROC) curve, was 0.887 (0.845-0.922). The 25% test ECGs with the lowest error estimates had an area under the ROC curve as high as 0.995 (0.982-1.000), i.e. almost all of these ECGs were correctly classified. Neural networks can therefore be trained to diagnose myocardial infarction and to signal when the advice is given with great confidence or when it should be considered more carefully. This method increases the possibility that artificial neural networks will be accepted as reliable decision support systems in clinical practice.
引用
收藏
页码:410 / 418
页数:9
相关论文
共 17 条
[1]  
[Anonymous], 1985, Eur Heart J, V6, P815
[2]   INTRODUCTION TO NEURAL NETWORKS [J].
CROSS, SS ;
HARRISON, RF ;
KENNEDY, RL .
LANCET, 1995, 346 (8982) :1075-1079
[3]   Detection of frequently overlooked electrocardiographic lead reversals using artificial neural networks [J].
Heden, B ;
Ohlsson, M ;
Holst, H ;
Mjoman, M ;
Rittner, R ;
Pahlm, O ;
Peterson, C ;
Edenbrandt, L .
AMERICAN JOURNAL OF CARDIOLOGY, 1996, 78 (05) :600-&
[4]   ARTIFICIAL NEURAL NETWORKS FOR THE ELECTROCARDIOGRAPHIC DIAGNOSIS OF HEALED MYOCARDIAL-INFARCTION [J].
HEDEN, B ;
EDENBRANDT, L ;
HAISTY, WK ;
PAHLM, O .
AMERICAN JOURNAL OF CARDIOLOGY, 1994, 74 (01) :5-8
[5]   Agreement between artificial neural networks and experienced electrocardiographer on electrocardiographic diagnosis of healed myocardial infarction [J].
Heden, B ;
Ohlsson, M ;
Rittner, R ;
Pahlm, O ;
Haisty, WK ;
Peterson, C ;
Edenbrandt, L .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 28 (04) :1012-1016
[6]   Acute myocardial infarction detected in the 12-lead ECG by artificial neural networks [J].
Heden, B ;
Ohlin, H ;
Rittner, R ;
Edenbrandt, L .
CIRCULATION, 1997, 96 (06) :1798-1802
[7]  
MACFARLANE PW, 1989, COMPREHENSIVE ELECTR, V3, P1527
[8]  
MacQueen J., 1967, Proceedings of 5th Berkeley Symposium on Mathematical Statistics and Probability, P281
[9]   SPECIFICITY AND SENSITIVITY OF QRS CRITERIA FOR DIAGNOSIS OF SINGLE AND MULTIPLE MYOCARDIAL INFARCTS [J].
PAHLM, O ;
HAISTY, WK ;
WAGNER, NB ;
POPE, JE ;
WAGNER, GS .
AMERICAN JOURNAL OF CARDIOLOGY, 1991, 68 (13) :1300-1304
[10]   JETNET 3.0 - A VERSATILE ARTIFICIAL NEURAL-NETWORK PACKAGE [J].
PETERSON, C ;
ROGNVALDSSON, T ;
LONNBLAD, L .
COMPUTER PHYSICS COMMUNICATIONS, 1994, 81 (1-2) :185-220