Sterile structural imaging of donor cornea by optical coherence tomography

被引:32
作者
Neubauer, AS
Priglinger, SG
Thiel, MJ
May, CA
Welge-Lüssen, UC
机构
[1] Univ Munich, Dept Ophthalmol, D-80336 Munich, Germany
[2] Univ Erlangen Nurnberg, Dept Anat, D-8520 Erlangen, Germany
关键词
cornea; diagnostic imaging; organ culture;
D O I
10.1097/00003226-200207000-00010
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. The purpose of the study was to demonstrate a new noncontact method for sterile measurement of structure and thickness of donor cornea with use of optical coherence tomography (OCT). Methods. A commercially available OCT instrument designed for retinal measurements was used for noncontact assessment of human corneas. Structural changes occurring during organ culture were evaluated in 29 corneas. Comparison with histology was performed. and the ability of OCT to detect corneal scars and corneal thickness was investigated. Results. Corneal epithelium, stroma, and posterior curvature, as well as thickness. can be measured by standard OCT while the cornea remains in its storage bottle. Epithelial changes leading to a reduction of epithelial thickness, stromal structural changes, and hydration folds can be visualized. OCT scans correlate well with histology. Preexisting and developing corneal scars can be detected by OCT. Conclusions. Corneal structural imaging can be performed under sterile conditions by OCT. This provides a method for improvement of corneal storage and a screening method for signs of photorefractive surgery and scarring in donor cornea.
引用
收藏
页码:490 / 494
页数:5
相关论文
共 36 条
[1]  
ANDERSEN J, 1987, ACTA OPHTHALMOL, V65, P293
[2]  
ANDERSEN J, 1988, ACTA OPHTHALMOL, V66, P313
[3]  
Beales MP, 1999, INVEST OPHTH VIS SCI, V40, P1658
[4]   Central corneal thickness measurement with a retinal optical coherence tomography device versus standard ultrasonic pachymetry [J].
Bechmann, M ;
Thiel, MJ ;
Neubauer, AS ;
Ullrich, S ;
Ludwig, K ;
Kenyon, KR ;
Ulbig, MW .
CORNEA, 2001, 20 (01) :50-54
[5]   A NEW SYSTEM FOR STORING DONOR CORNEAS [J].
BOHNKE, M .
KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1991, 198 (02) :135-137
[6]   Light microscopic evaluation of human donor corneal stroma during organ culture [J].
Borderie, V ;
Martinache, C ;
Sabolic, V ;
Touzeau, O ;
Laroche, L .
ACTA OPHTHALMOLOGICA SCANDINAVICA, 1998, 76 (02) :154-157
[7]   IN-VITRO MODEL FOR CORNEAL WOUND-HEALING - ORGAN-CULTURED HUMAN CORNEAS [J].
COLLIN, HB ;
ANDERSON, JA ;
RICHARD, NR ;
BINDER, PS .
CURRENT EYE RESEARCH, 1995, 14 (05) :331-339
[8]   ULTRASTRUCTURE OF HUMAN ORGAN-CULTURED CORNEA [J].
DOUGHMAN, DJ ;
VANHORN, D ;
HARRIS, JE ;
MILLER, GE ;
LINDSTROM, R ;
GOOD, RA .
ARCHIVES OF OPHTHALMOLOGY, 1974, 92 (06) :516-523
[9]  
EBATO B, 1987, INVEST OPHTH VIS SCI, V28, P1450
[10]   Corneal transplantation with donor tissue kept in organ culture for 7 weeks [J].
Ehlers, H ;
Ehlers, N ;
Hjortdal, JO .
ACTA OPHTHALMOLOGICA SCANDINAVICA, 1999, 77 (03) :277-278