Estimating test-retest reliability in functional MR imaging .1. Statistical methodology

被引:98
作者
Genovese, CR [1 ]
Noll, DC [1 ]
Eddy, WF [1 ]
机构
[1] UNIV PITTSBURGH,MED CTR,DEPT RADIOL,PITTSBURGH,PA
关键词
functional MRI; reliability; statistical methods; maximum likelihood;
D O I
10.1002/mrm.1910380319
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A common problem in the analysis of functional magnetic resonance imaging (fMRI) data is quantifying the statistical reliability of an estimated activation map. While visual comparison of the classified active regions across replications of an experiment can sometimes be informative, it is typically difficult to draw firm conclusions by inspection; noise and complex patterns in the estimated map make it easy to be misled. Here, several statistical models, of increasing complexity, are developed, under which ''test-retest'' reliability can be meaningfully defined and quantified. The method yields global measures of reliability that apply uniformly to a specified set of brain voxels. The estimates of these reliability measures and their associated uncertainties under these models can be used to compare statistical methods, to set thresholds for detecting activation, and to optimize the number of images that need to be acquired during an experiment.
引用
收藏
页码:497 / 507
页数:11
相关论文
共 13 条
[1]  
BAKER JR, 1994, P 2 ANN M SOC MAGN R, P626
[2]   PROCESSING STRATEGIES FOR TIME-COURSE DATA SETS IN FUNCTIONAL MRI OF THE HUMAN BRAIN [J].
BANDETTINI, PA ;
JESMANOWICZ, A ;
WONG, EC ;
HYDE, JS .
MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (02) :161-173
[3]   FUNCTIONAL CONNECTIVITY IN THE MOTOR CORTEX OF RESTING HUMAN BRAIN USING ECHO-PLANAR MRI [J].
BISWAL, B ;
YETKIN, FZ ;
HAUGHTON, VM ;
HYDE, JS .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (04) :537-541
[4]  
DeGroot M. H., 1991, PROBABILITY STAT
[5]   Improved image registration by using Fourier interpolation [J].
Eddy, WF ;
Fitzgerald, M ;
Noll, DC .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (06) :923-931
[6]  
EDDY WF, 1996, P COMP STAT, P39
[7]  
EFRON B, 1978, BIOMETRIKA, V65, P457, DOI 10.1093/biomet/65.3.457
[8]   IMPROVED ASSESSMENT OF SIGNIFICANT ACTIVATION IN FUNCTIONAL MAGNETIC-RESONANCE-IMAGING (FMRI) - USE OF A CLUSTER-SIZE THRESHOLD [J].
FORMAN, SD ;
COHEN, JD ;
FITZGERALD, M ;
EDDY, WF ;
MINTUN, MA ;
NOLL, DC .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) :636-647
[9]  
Lehmann EL, 1975, NONPARAMETRICS
[10]  
Lindsay B., 1995, NSF CBMS REGIONAL C, V5, DOI DOI 10.1214/CBMS/1462106013