Ultrasound Doppler estimates of femoral artery blood flow during dynamic knee extensor exercise in humans

被引:240
作者
Radegran, G
机构
[1] Copenhagen Muscle Research Centre, Rigshospitalet
关键词
blood velocity; flow profile; vessel diameter;
D O I
10.1152/jappl.1997.83.4.1383
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Ultrasound Doppler has been used to measure arterial inflow to a human limb during intermittent static contractions. The technique, however, has neither been thoroughly validated nor used during dynamic exercise. In this study, the inherent problems of the technique have been addressed, and the accuracy was improved by storing the velocity tracings continuously and calculating the flow in relation to the muscle contraction-relaxation phases. The femoral arterial diameter measurements were reproducible with a mean coefficient of variation within the subjects of 1.2 +/- 0.2%. The diameter was the same whether the probe was fixed or repositioned at rest (10.8 +/- 0.2 mm) or measured during dynamic exercise. The blood velocity was sampled over the width of the diameter and the parabolic velocity profile, since sampling in the center resulted in an overestimation by 22.6 +/- 9.1% (P < 0.02). The femoral arterial Doppler blood flow increased linearly (r = 0.997, P < 0.001) with increasing load [Doppler blood flow = 0.080.load (W) + 1.446 l/min] and was correlated positively with simultaneous thermodilution venous outflow measurements (r =; 0.996, P < 0.001). The two techniques were linearly related (Doppler = thermodilution.0.985 + 0.071 l/min; r = 0.996, P < 0.001), with a coefficient of variation of similar to 6% for bath methods.
引用
收藏
页码:1383 / 1388
页数:6
相关论文
共 17 条
[1]   MAXIMAL PERFUSION OF SKELETAL-MUSCLE IN MAN [J].
ANDERSEN, P ;
SALTIN, B .
JOURNAL OF PHYSIOLOGY-LONDON, 1985, 366 (SEP) :233-249
[2]   DYNAMIC KNEE EXTENSION AS MODEL FOR STUDY OF ISOLATED EXERCISING MUSCLE IN HUMANS [J].
ANDERSEN, P ;
ADAMS, RP ;
SJOGAARD, G ;
THORBOE, A ;
SALTIN, B .
JOURNAL OF APPLIED PHYSIOLOGY, 1985, 59 (05) :1647-1653
[3]   THE BLOOD FLOW THROUGH THE HUMAN CALF DURING RHYTHMIC EXERCISE [J].
BARCROFT, H ;
DORNHORST, AC .
JOURNAL OF PHYSIOLOGY-LONDON, 1949, 109 (3-4) :402-&
[4]   MUSCLE BLOOD FLOW DURING EXERCISE IN NORMAL MAN STUDIED BY XENON-133 CLEARANCE METHOD [J].
CLAUSEN, JP ;
LASSEN, NA .
CARDIOVASCULAR RESEARCH, 1971, 5 (02) :245-+
[5]   MEASUREMENT OF BLOOD FLOW IN FEMORAL ARTERY IN MAN AT REST + DURING EXERCISE BY LOCAL THERMODILUTION [J].
GANZ, V ;
HLAVOVA, A ;
FRONEK, A ;
LINHART, J ;
PREROVSKY, I .
CIRCULATION, 1964, 30 (01) :86-+
[6]  
GILL R W, 1979, Ultrasound in Medicine and Biology, V5, P223, DOI 10.1016/0301-5629(79)90014-0
[8]  
Holtz J., 1996, P1865
[9]   MEASUREMENT OF ARTERIAL BLOOD-FLOW BY DOPPLER ULTRASOUND [J].
HOSKINS, PR .
CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1990, 11 (01) :1-26
[10]  
INGEMANNHANSEN T, 1977, SCAND J REHABIL MED, V9, P67