Experimental work on a linked, dynamic and ventilated, wall component

被引:52
作者
Dimoudi, A
Androutsopoulos, A
Lykoudis, S
机构
[1] Minist Environm Phys Planning & Publ Works, Directory Housing Policy & Shelter, Athens 11525, Greece
[2] Ctr Renewable Energy Sources, Athens 19009, Greece
[3] Natl Observ Athens, Athens 15236, Greece
关键词
dynamic insulation; ventilated wall;
D O I
10.1016/j.enbuild.2004.01.048
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In a conventional construction, the ventilation air enters the building through a combination of pathways, such as windows and vents, via cracks around external openings, joints between building materials, etc. By contrast, in a dynamic insulation construction, the ventilation air is drawn into the building through the insulation material of the building envelope. Structures with dynamic insulation incorporate porous insulating material in the envelope and air passes through the porous material. The aim of this paper is to present the experimental work carried out on a wall component that is a combination of dynamic insulation panel and a ventilated facade, tested under real weather conditions. The wall component consisted of two main sub-layers: the ventilated external envelope and the dynamic insulation (DI) sub-layer. The DI component consisted of layers of breathing materials that let the air enter the room at a reasonable pressure difference between the interior and exterior. The paper describes the experimental work carried out and the results drawn from the tests performed in the linked wall component under: (i) various differential pressure regimes between the interior and the exterior of the test cell and (ii) controlled and floating internal air temperature. In summary, the performance of the component was effective, since conduction losses were decreasing. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:443 / 453
页数:11
相关论文
共 17 条
[1]  
[Anonymous], 1993, P 3 S BUILD PHYS NOR
[2]  
BRUNSELL JT, 1995, AIF INFILTRATION REV, V16
[3]  
CAWTHORNE D, 1997, TRANSLUCENT DYNAMIC
[4]  
CLARE A, 2001, P 22 ANN AIVC C MARK
[5]  
CROWTHER D, 2000, JOE3CT977003 AIRINST
[6]  
CROWTHER D, 1994, THESIS CAMBRIDGE U
[7]  
LIDELL H, 1996, CIBSE ASHRAE JOINT N, V2
[8]  
MULLIGAN H, 2000, JOE3CT977003 AIRINST
[9]  
ROOTS P, 1993, P 3 S BUILD PHYS NOR, V1, P227
[10]   The building envelope as an air filter [J].
Taylor, BJ ;
Webster, R ;
Imbabi, MS .
BUILDING AND ENVIRONMENT, 1999, 34 (03) :353-361