phospholipid polymer; oxyethylene chain; blood compatibility; protein adsorption; gold-colloid labeled immunoassay; platelet adhesion; HUMAN PLASMA-PROTEINS; BLOOD COMPATIBILITY; PHOSPHORYLCHOLINE MOIETY; POLY(ETHYLENE OXIDE); COATING MATERIAL; VASCULAR GRAFTS; SIDE-CHAIN; HEMOCOMPATIBILITY; THROMBOGENICITY; BIOMATERIALS;
D O I
10.1163/156856296X00174
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We evaluated the blood compatibility of various amphiphilic polymers, that is, n-butyl methacrylate (BMA) copolymers with methacrylates having a phosphorylcholine (PC), hydroxy (OH) or methoxy (MeO) group as an end polar group in the oxyethylene side chain. The amount of proteins adsorbed on the PC-polymer from human plasma was smaller than that on not only the poly(2-hydroxyethyl methacrylate) and poly(methyl methacrylate) but also the OH-polymer and MeO-polymer. The PC group could weaken the interaction between plasma proteins and polymer surfaces. The amount of adsorbed proteins on the PC-polymer decreased with an increase in the mole fraction of the PC units in the polymers. We could observe an effect of the oxyethylene chain length (n is the number of repeating units of oxyethylene) on protein adsorption between n=2 and n=3. The platelet adhesion on these polymer surfaces was evaluated using rabbit platelet-rich plasma. On the polymers without the PC group, that is, poly(BMA), OH-polymer, and MeO-polymer, many platelets adhered and a considerable shape change in the adherent platelets occurred. On the other hand, the PC-polymers could effectively suppress platelet adhesion. The platelet adhesion behavior on the polymers was strongly dependent on the adsorbed proteins. Platelet adhesion was completely inhibited on all of the PC-polymers studied having a 0.3 PC unit mole fraction. However, it was observed that the oxyethylene chains on the PC-polymers with a 0.1 PC unit mole fraction affected platelet adhesion.
引用
收藏
页码:91 / 102
页数:12
相关论文
共 45 条
[1]  
Akizawa T, 1989, ASAIO Trans, V35, P333
[2]  
AKIZAWA T, 1986, T AM SOC ART INT ORG, V32, P76
[3]  
Andrade J.D., 1985, SURFACE INTERFACIAL, P105, DOI [DOI 10.1007/978-1-4684-8610-0_5, 10.1007/978-1-4684-8610-0_5]
[4]  
Antonsen K.P., 1992, Poly (Ethylene Glycol) Chemistry, P15
[5]   REDUCTION OF FIBRINOGEN ADSORPTION ON PEG-COATED POLYSTYRENE SURFACES [J].
BERGSTROM, K ;
HOLMBERG, K ;
SAFRANJ, A ;
HOFFMAN, AS ;
EDGELL, MJ ;
KOZLOWSKI, A ;
HOVANES, BA ;
HARRIS, JM .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1992, 26 (06) :779-790
[6]  
BERGSTROM K, 1994, J BIOMAT SCI-POLYM E, V6, P123
[7]   INTERACTIONS OF POLYMERIZABLE PHOSPHATIDYLCHOLINE VESICLES WITH BLOOD COMPONENTS - RELEVANCE TO BIOCOMPATIBILITY [J].
BONTE, F ;
HSU, MJ ;
PAPP, A ;
WU, K ;
REGEN, SL ;
JULIANO, RL .
BIOCHIMICA ET BIOPHYSICA ACTA, 1987, 900 (01) :1-9
[8]   PEO ENHANCEMENT OF PLATELET DEPOSITION, FIBRINOGEN DEPOSITION, AND COMPLEMENT C3 ACTIVATION [J].
CHAIKOF, EL ;
MERRILL, EW ;
CALLOW, AD ;
CONNOLLY, RJ ;
VERDON, SL ;
RAMBERG, K .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1992, 26 (09) :1163-1168
[9]   BIOMATERIALS FOR BLOOD-CONTACTING APPLICATIONS [J].
COURTNEY, JM ;
LAMBA, NMK ;
SUNDARAM, S ;
FORBES, CD .
BIOMATERIALS, 1994, 15 (10) :737-744
[10]  
Gennis R.B., 1989, BIOMEMBRANES MOL STR