First-year outcomes of beating heart coronary artery bypass grafting using proximal mechanical connectors

被引:21
作者
Dewey, TM
Crumrine, K
Herbert, MA
Leonard, A
Prince, SL
Worley, C
Edgerton, JR
Magee, MJ
Mack, MJ
机构
[1] Med City Dallas Hosp, Dept Clin Res, Dallas, TX USA
[2] Med City Dallas Hosp, Cardiopulm Res Sci & Technol Inst, Dallas, TX USA
关键词
D O I
10.1016/j.athoracsur.2003.09.047
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. To determine the extended results of mechanical connectors we compared the 1-year outcomes of patients having beating heart coronary artery bypass surgery with at least one sutured or mechanically connected proximal vein graft anastomosis. Methods. From May 2001 to December 2001, 166 patients were identified as having undergone off-pump bypass grafting utilizing at least one St. Jude symmetry aortic connector (St Jude Medical Anastomotic Technology Group, St. Paul, MN). Follow-up for major adverse cardiac events (MACEs), which is defined as cardiac mortality, myocardial infarction, or revascularization of a previous target vessel, was obtained on 162 patients (97.6%). A control group of 159 patients was identified from a cohort of patients having beating heart surgery with one or more sutured proximal vein graft anastomosis in the preceding year. The MACE follow-ups were obtained in 136 patients (85.6%) by direct telephone contact. Results. Patients with connectors showed an accelerated number of MACEs beginning approximately 180 days from the time of surgery and stabilizing at approximately 300 days. Logistic regression analysis identified the presence of diabetes as a significant preoperative risk factor predisposing patients to earlier onset of MACEs (p = 0.03) with an odds ratio of 2.9 (95% confidence interval, 1.1 to 7.6). Insulin dependent diabetics showed no differences between connector and control patients in the frequency or timing of MACEs. Connector patients using oral hypoglycemic agents demonstrated a significant deviation (p = 0.01) from a similar control population in the prevalence and timing of MACEs. Conclusions. Connector patients showed an increased incidence of early MACEs. These events were characterized by an increased requirement for early target vessel revascularization and were predominantly in noninsulin-dependent diabetics. (C) 2004 by The Society of Thoracic Surgeons.
引用
收藏
页码:1542 / 1549
页数:8
相关论文
共 24 条
[1]  
ABBE R, 1894, NY MED J, V59, P33
[2]   The influence of diabetes mellitus on acute and late clinical outcomes following coronary stent implantation [J].
Abizaid, A ;
Kornowski, R ;
Mintz, GS ;
Hong, MK ;
Abizaid, AS ;
Mehran, R ;
Pichard, AD ;
Kent, KM ;
Satler, LF ;
Wu, HS ;
Popma, JJ ;
Leon, MB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (03) :584-589
[3]  
ANDROSOV PI, 1956, ARCH SURG-CHICAGO, V73, P902
[4]   Aortic atheromatosis and risks of cerebral embolization [J].
Barbut, D ;
Gold, JP .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1996, 10 (01) :24-30
[5]  
BAYES JW, 1991, DIABETES, V40, P937
[6]   Early clinical experience with a new sutureless anastomotic device for proximal anastomosis of the saphenous vein to the aorta [J].
Calafiore, AM ;
Bar-El, Y ;
Vitolla, G ;
Di Giammarco, G ;
Teodori, G ;
Iacò, AL ;
D'Alessandro, S ;
Di Mauro, M .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2001, 121 (05) :854-858
[7]  
Carrel A., 1902, LYON MED, V98, P859
[8]  
Chavanon O, 1999, ANN THORAC SURG, V68, P1443
[9]   The St Jude Medical symmetry aortic connector system for proximal vein graft anastomoses in coronary artery bypass grafting [J].
Eckstein, FS ;
Bonilla, LF ;
Englberger, L ;
Immer, FF ;
Berg, TA ;
Schmidli, J ;
Carrel, TP .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 123 (04) :777-782
[10]   Minimizing aortic manipulation during OPCAB using the symmetry aortic connector system for proximal vein graft anastomoses [J].
Eckstein, FS ;
Bonilla, LF ;
Englberger, L ;
Stauffer, E ;
Berg, TA ;
Schmidli, J ;
Carrel, TP .
ANNALS OF THORACIC SURGERY, 2001, 72 (03) :S995-S998